Risk assessment of healthcare workers' exposure to physical load in relation to patient handling and movement: a feasibility study of the instrument TilThermometer
Linköping University, Department of Health, Medicine and Caring Sciences, Division of Prevention, Rehabilitation and Community Medicine. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Medicine Center, Occupational and Environmental Medicine Center. Karolinska Inst, Sweden.ORCID iD: 0000-0001-7847-7528
Linköping University, Department of Health, Medicine and Caring Sciences, Division of Prevention, Rehabilitation and Community Medicine. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Medicine Center, Occupational and Environmental Medicine Center.ORCID iD: 0000-0002-8925-5952
Linköping University, Department of Health, Medicine and Caring Sciences, Division of Prevention, Rehabilitation and Community Medicine. Linköping University, Faculty of Medicine and Health Sciences.ORCID iD: 0000-0003-3707-5869
Linköping University, Department of Health, Medicine and Caring Sciences, Division of Prevention, Rehabilitation and Community Medicine. Linköping University, Faculty of Medicine and Health Sciences.ORCID iD: 0000-0001-8962-196X
Show others and affiliations
2024 (English)In: BMC Musculoskeletal Disorders, E-ISSN 1471-2474, Vol. 25, no 1, article id 399Article in journal (Refereed) Published
Abstract [en]

Background Work-related musculoskeletal disorders are common among healthcare workers (HCWs) but might be prevented by risk assessment and further promotion of occupational safety and health. The aim of this study was to investigate if the risk assessment instrument TilThermometer can be used to identify risk profiles of physical exposure in HCWs working with patient handling and movement (PHM). Further aims were to describe HCWs' perceptions and experiences of using the TilThermometer.Background Work-related musculoskeletal disorders are common among healthcare workers (HCWs) but might be prevented by risk assessment and further promotion of occupational safety and health. The aim of this study was to investigate if the risk assessment instrument TilThermometer can be used to identify risk profiles of physical exposure in HCWs working with patient handling and movement (PHM). Further aims were to describe HCWs' perceptions and experiences of using the TilThermometer.Methods This feasibility study has a mixed design methodology. In total, 54 HCWs from 17 Swedish care units participated and performed risk assessments with the TilThermometer. Data collected from the risk assessments were used to identify risk profiles of physical exposure. HCWs' experiences of using the TilThermometer were collected from activity logs and analysed qualitatively. Three questionnaires were used to assess perceived acceptability, appropriateness, and feasibility of the risk assessment, and eight study specific questions were used for perceived usefulness.Results The TilThermometer was used at the care units by assessing each care recipient, and when compiling the data at a group level, a summarized risk profile for the care unit could be provided. Risk for physical exposure was reported as high in two work tasks; no care unit used the high-low adjustable seat when showering care recipients sitting down, and 13% used the recommended assistive devices when putting compression stockings on. However, 99% used high-low adjustable assistive devices when caring and bathing care recipients lying down. TilThermometer was described as easy to use, enabling team reflections and providing an overview of the care units' recipients and workload, but difficulties in categorizing for mobility groups were also reported. The TilThermometer was, on a five-point scale, perceived as acceptable (mean 3.93), appropriate (mean 3.9), and feasible (mean 3.97). These scores are in line with questions evaluating usefulness.Conclusion The risk assessment provided risk profiles with potential to contribute to care units' development of a safe patient handling and movement practice. The findings suggest that the TilThermometer can be used to assess risks for physical exposure in relation to patient handling and movement in care units at hospital and nursing homes.

Place, publisher, year, edition, pages
BMC , 2024. Vol. 25, no 1, article id 399
Keywords [en]
Occupational health; Ergonomics; Nursing; Risk assessment; Health personnel workers; Safety management; Working conditions environment
National Category
Occupational Health and Environmental Health
Identifiers
URN: urn:nbn:se:liu:diva-204333DOI: 10.1186/s12891-024-07508-9ISI: 001228658400005PubMedID: 38773516OAI: oai:DiVA.org:liu-204333DiVA, id: diva2:1868594
Note

Funding Agencies|AFA Frskring

Available from: 2024-06-12 Created: 2024-06-12 Last updated: 2024-06-12

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
Wåhlin, CharlotteBuck, SebastianEnthoven, PaulAndreassen, MariaSandqvist, JanFock, Jenni
By organisation
Division of Prevention, Rehabilitation and Community MedicineFaculty of Medicine and Health SciencesOccupational and Environmental Medicine CenterRegional utveckling
In the same journal
BMC Musculoskeletal Disorders
Occupational Health and Environmental Health

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 104 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf