liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Säsongsvis reglering avspänningsnivån imellanspänningsnätet: En studie i hur säsongsvis reglering av börvärdet imellanspänningsnätet kan minska sannolikheten föröverspänning i lågspänningsnätet till följd av solceller
Linköping University, Department of Electrical Engineering.
Linköping University, Department of Electrical Engineering.
2024 (Swedish)Independent thesis Advanced level (degree of Master (Two Years)), 28 HE creditsStudent thesis
Abstract [en]

In today’s society we are witnessing an electrification coupled with a surge in consumption of electricity. Consequently, there has been a notable increase of intergration of renewable energy sources, such as solar and wind power, onto the powergrid. Specifically, solar photovoltaic (PV) installations have experienced a substantial growth in recent years, predominantly among residential consumers, but also aslarger solar parks.

The operation of the Swedish power grid has, over the past decades, prioritizedfunctionality over further development of the grid. However, the significant rise inprivate solar PV installations present scenarios for which the grid was not initiallyequipped for. An example of this is the occurence of high voltages at residentialpremises when solar panels produces more electricity than the household consumes,resulting in reverse power flows.

The objective of this study has been to investigate the feasibility of dynamic voltageregulation through the implementation of a seasonally adjusted setpoint in the powertransformers of the 11 kV grid, aiming to mitigate overvoltage and undervoltage inthe low voltage grid. The studied network encompassed an area served by an existingtransformer station. To achieve this objective, the following questions were adressed:

1. What should be the appropriate setpoint seasonally for the tap changer toadjust the voltage of the secondary side of the medium voltage grid OLTC-transformer station 130 / 11 kV, in order to reduce the risk of overvoltage at 440 V without increasing the risk of undervoltage at 360 V?

2. How does the risk of overvoltage and undervoltage change by alternative mea-sures, such as consumption of reactive power in PV inverters or local ad-justment of the tap changers in the grid stations distribution transformers 11 / 0,42 kV?

Two case scenarios, consisting of two 11 kV grids and all of their repective 0,42 kV grids, were simulated using MATLAB to replicate segments of the grid, operated by the local utility company. The results indicated that reducing the setpoint by 1,67 % during the summer led to a decrease in the number of hours experiencing undesired overvoltage, without a significant increase in the likelihood of undervoltage. Further reduction of the setpoint by a total of 3,34 % eliminated all instances ofundesired overvoltage, but resulted in an increase in undesired undervoltage. Conversely, during the winter, increasing the setpoint resulted in undesired overvoltagein the network. Alternative measures, including reactive power consumption by PV inverters and local adjustment of tap changers, were analyzed in the most vulnerablelow voltage grid of the two case scenarios. Both measures eliminated all instancesof undesired voltage fluctuations during both summer and winter.

Based on the findings, it is concluded that during the summer, a reduction of thesetpoint by 1,67 % is advisable, while during the winter, no adjustment of the setpoint is recommended. However, it is important to note that the results should beconsidered indicitive and supportive of the proposed action, as only two of the ninefeeders in the grid were investigated. Furthermore, the results from alternative measures suggest the potential efficacy of more targeted interventions with less impacton the overall grid, compered to a seasonally adjusted setpoint.

Place, publisher, year, edition, pages
2024. , p. 71
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering Energy Engineering
Identifiers
URN: urn:nbn:se:liu:diva-205125ISRN: LiTH-ISY-EX--24/5676--SEOAI: oai:DiVA.org:liu-205125DiVA, id: diva2:1874135
External cooperation
Tekniska verken AB
Supervisors
Examiners
Available from: 2024-06-20 Created: 2024-06-19 Last updated: 2024-06-20Bibliographically approved

Open Access in DiVA

fulltext(1298 kB)269 downloads
File information
File name FULLTEXT01.pdfFile size 1298 kBChecksum SHA-512
8e9a284159acd1623a07451f1a8a564dd690bf4a303ad4b8e2992334579b38c2cf88b1eb37a6dccfbda4f83118d713ca26d29131504ece2786eea91cd64c89ec
Type fulltextMimetype application/pdf

By organisation
Department of Electrical Engineering
Other Electrical Engineering, Electronic Engineering, Information EngineeringEnergy Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 270 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 450 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf