Analys av lagerströmmar i industriella maskiner: En fallstudie på en modern kartongmaskin
Linköping University, Department of Electrical Engineering.
Linköping University, Department of Electrical Engineering.
2024 (Swedish)Independent thesis Basic level (university diploma), 14 HE creditsStudent thesis
Abstract [sv]

Detta arbete undersöker och analyserar förekomsten av lagerströmmar i industriella elmaskiner, med fokus på en produktionsanläggning för kartongprodukter. Lagerströmmar är oönskade strömmar som passerar genom kullagren och kan påverka elmaskinens livslängd och dess prestanda negativt. Syftet med arbetet är att ge förståelse för hur lagerströmmar uppstår och att diskutera effektiva åtgärder för att detektera och hantera dem. 

Genom att detektera urladdningar från maskinernas roterande axel identifierades vilka maskiner som var drabbade av skadliga lagerströmmar. På grund av begränsningar som otillgänglighet, platsbrist och säkerhetsrisker kunde inte mätningar utföras på alla maskiner i anläggningen. Trots viss osäkerhet i mätresultaten anses den använda metoden tillräckligt pålitlig för att kunna ge indikationer på förekomsten av skadliga lagerströmmar.

Abstract [en]

This work investigates and analyzes the occurrence of bearing currents in industrial electric machines, focusing on a cardboard production facility. Bearing currents are undesired currents that pass through the bearings and can negatively affect the machine's lifespan and performance. The purpose of this work is to understand the origins of bearing currents and to discuss effective measures for detecting and managing them.

By detecting discharges from the machines' rotating shafts, the affected machines with harmful bearing currents were identified. Due to limitations such as inaccessibility, space constraints, and safety risks, measurements could not be conducted on all machines in the facility. Despite some uncertainty in the measurement results, the method used is considered sufficiently reliable to provide indications of the presence of harmful bearing currents.

Place, publisher, year, edition, pages
2024. , p. 30
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:liu:diva-205855ISRN: LiTH-ISY-EX-ET--24/0530--SEOAI: oai:DiVA.org:liu-205855DiVA, id: diva2:1883320
Subject / course
Vehicular Systems
Presentation
2024-06-20, Visionen, Linköping, 13:15 (Swedish)
Supervisors
Examiners
Available from: 2024-07-11 Created: 2024-07-09 Last updated: 2024-07-11Bibliographically approved

Open Access in DiVA

fulltext(33750 kB)314 downloads
File information
File name FULLTEXT01.pdfFile size 33750 kBChecksum SHA-512
a777e9da1d8c18f3133d1e2097bcfea46ec37544b2303b64c780f15cbcf467890de46beca5c0540afce79f9bb2db9259f7da4aa47984e2b58fe96e1d97f0ea69
Type fulltextMimetype application/pdf

By organisation
Department of Electrical Engineering
Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 317 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 535 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf