EMF Simulations in the MR-Safety Assessment of Implantable Medical Devices: Case study of multi-stents
Linköping University, Department of Health, Medicine and Caring Sciences.
2024 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

The aim of the study was to perform electromagnetic field (EMF) simulations and thermal simulations of passive medical implants to assist in the magnetic resonance (MR) safety assessment. The study focused on stents, and specifically on the effect different dimensions and configurations may have on the heating effects, when exposed to RF pulses. Since computer simulations were used, it was also desirable to discuss possible simplifications that could decrease the simulation time in more complex models. The stents were simplified as metallic wires and the RF pulses as harmonic plane waves. The studied frequencies were 64 MHz and 128 MHz (corresponding to a 1.5 T and 3 T MR scan) and the exposure time was 1 h. The results showed that the dimensions and configurations are important to consider when deciding on patient safety, because some configurations could be more hazardous than others. The main findings follow:

  • For highly conductive materials it was deemed reasonable to approximate them as perfect electric conductors.
  • At 64 MHz a wire length of 175 mm resulted in the highest temperature reading while at 128 MHz it was the 100 mm long wire.
  • The smaller the radius of the wire the higher the peak temperature got.
  • The usage of a smaller radius may shorten the simulation time, without decreasing the peak temperature.
  • The closer two wires were, while separated and placed along the same axis, the higher the maximal temperature got. The peak temperature was found in the gap separating the wires and it was significantly higher than at the outer tip.
  • Placing the wire in the same direction as the electric field resulted in the strongest interaction between the two.

There are many aspects to consider when studying EMFs, and the research field of EMF simulations is vast. In this study, the focus was on the general aspects for potential tissue heating of patients with implanted stents, when exposed to the RF-fields in MR scans. The results accentuate the importance of evaluating each and every case to ensure safe examinations.

Place, publisher, year, edition, pages
2024.
National Category
Other Medical Engineering
Identifiers
URN: urn:nbn:se:liu:diva-208521OAI: oai:DiVA.org:liu-208521DiVA, id: diva2:1905653
External cooperation
Region Östergötland
Presentation
2024-09-19, 11:00 (English)
Supervisors
Examiners
Available from: 2024-10-15 Created: 2024-10-14 Last updated: 2024-10-15Bibliographically approved

Open Access in DiVA

Master's Thesis(2837 kB)237 downloads
File information
File name FULLTEXT01.pdfFile size 2837 kBChecksum SHA-512
025cf2d502ec239628e5f08e5df0c1a467d7205d0a1542e76f835a0afdd374f3bac70665e2f9c1312dbc2867bd8d15823e023611ec1ff8c062e2bda4aa0e578d
Type fulltextMimetype application/pdf

By organisation
Department of Health, Medicine and Caring Sciences
Other Medical Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 240 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 285 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf