Abstract [en]
Durable left ventricular assist device (LVAD) therapy has been revolutionised by the HeartMate 3™ (HM3), a fully magnetically levitated centrifugal pump, offering superior haemocompatibility and durability. However, long-term outcomes remain limited by complications such as aortic regurgitation (AR), right ventricular failure (RHF), and extrinsic outflow graft obstruction (eOGO). The current clinical standard for haemodynamic monitoring, echocardiography, is restricted by poor acoustic windows caused by the metallic body of the device. The overarching aim of this thesis was to investigate how HM3 therapy interacts with the native heart´s function and haemodynamics, employing photon-counting computed tomography (PCCT) as the foundation for new advanced imaging approaches.
The thesis comprises five papers. Paper I systematically reviewed echocardiographic evidence in HM3 recipients specifically, identifying AR, RHF, and interventricular interplay as key unresolved challenges. Paper II optimised PCCT acquisition and reconstruction protocols, demonstrating that tailored strategies can markedly reduce metal artefacts. Paper III combined PCCT-derived geometries with computational fluid dynamics (CFD) in cases of suspected eOGO, showing that anatomical narrowing does not invariably result in haemodynamic compromise. Paper IV applied a more advanced CFD-modelling approach at different degrees of AR, revealing that even mild regurgitation can induce a blind-loop circulation, a haemodynamic phenomenon with substantial loss of effective systemic output when the loop-circulation increases. Paper V analysed right ventricular volumetric variables across varying pump speeds, demonstrating progressive dilatation and reduced ejection fraction at higher speeds, with impaired contractile reserve – changes that could not be detected by concomitant echocardiographic variables.
In conclusion, by integrating artefact-reduced PCCT with image processing and flow modelling, this thesis provides mechanistic insights into device-heart interactions that cannot be captured by conventional methods. The findings indicate that radiologically identified graft stenoses may lack haemodynamic significance, that AR can markedly reduce effective output through blind-loop circulation, and that RV maladaptation at higher pump speeds may remain unnoticed by standard monitoring.
Place, publisher, year, edition, pages
Linköping: Linköping University Electronic Press, 2025. p. 73
Series
Linköping University Medical Dissertations, ISSN 0345-0082 ; 1999
National Category
Cardiology and Cardiovascular Disease
Identifiers
urn:nbn:se:liu:diva-218257 (URN)10.3384/9789181182545 (DOI)9789181182538 (ISBN)9789181182545 (ISBN)
Public defence
2025-11-06, Granitsalen, building 440, Campus US, Linköping, 13:00 (English)
Opponent
Supervisors
Note
Funding: This work has been conducted in collaboration with the Center for Medical Image Science and Visualization (CMIV) at Linköping University, Sweden. CMIV is acknowledged for the provision of financial support and research infrastructure.
The computations were enabled by resources provided by the National Academic Infrastructure for Supercomputing in Sweden (NAISS), the Swedish National Infrastructure for Computing (SNIC), and the National Supercomputer Centre (NSC).
Furthermore, the Foundation Linköpings Läkarsällskap and Region Östergötland are acknowledged for financial support.
2025-10-022025-10-022025-10-02Bibliographically approved