liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Examination of Coronary Artery Disease with Computed Tomography: Stenosis Evaluation and Calcium Score
Linköping University, Department of Health, Medicine and Caring Sciences, Division of Diagnostics and Specialist Medicine. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Center for Diagnostics, Department of Radiology in Linköping.ORCID iD: 0000-0001-5485-6769
2024 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Computed tomography (CT) is increasingly utilized for evaluating patients with suspected coronary artery disease (CAD). Advancements in CT technology have the potential to enhance diagnostic accuracy and streamline clinical workflows for this patient group.

The overarching objective of this thesis was to investigate the role of CT in the assessment of CAD. Specifically, studies focused on evaluating emerging technologies: Stenosis evaluation with transluminal attenuation gradients (TAG) (study I), an AI-based calcium scoring CT (CSCT) software prototype (study II), photon-counting detector (PCD) CT for CSCT evaluations (study III) and a commercially available AI-based CSCT software was evaluated using a large dataset from the Swedish Cardiopulmonary bioImage Study (SCAPIS) (study IV).

Studies I and II evaluating TAG and the CSCT software prototype were based on clinical patient data, while the PCD-CT evaluation (study III) used CT data of cadaveric hearts and the commercially AI-based CSCT software was evaluated using data of SCAPIS study subjects (study IV). The performance of TAG was compared to invasive fractional flow reserve (FFR) measurements (study I), while CSCT AI-based softwares were benchmarked against semi-automated coronary artery calcification (CAC) scoring by human readers (study II and IV). In study III, the PCD-CT performance regarding CAC quantification was compared to results from energy-integrating detector (EID) CT.

TAG did not demonstrate any value for the evaluation of coronary artery stenosis degree (study I). A result that is in alignment with other studies in the field. The evaluations of CSCT software demonstrated strong correlations and excellent agreement with standard reference measures (studies II and IV), along with significant time-saving potential (study II). PCD-CT showed strong correlation and agreement with EID-CT for CSCT evaluations using the well-established Agatston score, indicating that these measurements can be converted to the forthcoming detector technology for CT (study III).

Abstract [sv]

Datortomografisk koronarangiografi (DTKA) och utvärdering av kranskärlskalk (kalciumscore, DTKS) är väl etablerade metoder i den kliniska hanteringen av patienter med misstänkt kranskärlssjukdom. För att ytterligare förbättra diagnostiken, effektiviteten i den kliniska verksamheten och uppföljningsstrategier krävs fortsatt teknisk utveckling.

Syftet med denna avhandling var att fastställa värdet av nya tekniker för utvärdering av datortomografiundersökningar (DT) vid misstänkt kranskärlssjukdom. Den första studien fokuserade på utvärdering av stenoser i DTKA-bilder, två studier undersökte AI-baserade mjukvaror för bedömning av DTKS, och en studie granskade möjligheten att använda fotonräknar-DT (FRDT) för utvärdering av DTKS.

Den första studien utvärderade potentialen att förbättra bedömningen av kranskärlsstenoser med hjälp av den transluminala attenueringsgradienten (TAG). Teorin bakom TAG är att jodkontrastens fördelning längs kranskärlen återspeglar blodflödet, där signifikanta stenoser skulle resultera i större attenueringsförändringar jämfört med icke-signifikanta stenoser. TAG mättes både manuellt i den rutinmässiga postprocessingsmjukvaran för DTKA samt med en halvautomatisk specialiserad mjukvara. Resultaten jämfördes med tryckfallsmätningar över stenoser utförda i samband med invasiv koronarangiografi, som anses vara "gold standard" för utvärdering av kranskärlsstenoser. Studie II utvärderade en prototyp av en AI-baserad mjukvara för automatisk mätning av kalciumscore i DTKS-undersökningar. Även tiden för att generera resultaten registrerades, och dessa jämfördes med en standardreferens i form av en semi-automatisk kalciumscore-metod. Den tredje studien undersökte DTKS-resultat i bilder tagna med FRDT, en nyintroducerad detektorteknik som sannolikt kommer att bli standard i framtida DT-system, för att fastställa om denna teknik ger tillförlitliga resultat. Studie IV utvärderade en senare version av den AI-baserade mjukvara som tidigare undersökts i studie II. Här användes ett betydligt större dataset, bestående av DTKS-undersökningar utförda inom Swedish Cardiopulmonary bioImage Study (SCAPIS) i Linköping mellan 2015 och 2018.

TAG-mätningarna visade sig inte förbättra stenosbedömningen i DTKAundersökningar. Däremot visade AI-mjukvarorna en mycket god korrelation och överensstämmelse med standardmetoder för kalciumscore, och en tydlig tidsbesparande potential observerades i studie II. Utvärderingen av DTKS-bilder tagna med FRDT-system visade mycket god överensstämmelse med resultat från ett standard-DT-system.

Avhandlingen understryker vikten av teknisk utveckling inom DT för utredning av misstänkt kranskärlssjukdom. Resultaten kan bidra till förbättrad diagnostisk precision och effektivare utredningar, vilket i sin tur kan leda till en förbättrad hälsoekonomi.

Place, publisher, year, edition, pages
Linköping: Linköping University Electronic Press, 2024. , p. 121
Series
Linköping University Medical Dissertations, ISSN 0345-0082 ; 1939
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
URN: urn:nbn:se:liu:diva-209245DOI: 10.3384/9789180758093ISBN: 9789180758086 (print)ISBN: 9789180758093 (electronic)OAI: oai:DiVA.org:liu-209245DiVA, id: diva2:1911542
Public defence
2024-12-10, Belladonna, Building 511, Campus US, Linköping, 09:00 (English)
Opponent
Supervisors
Available from: 2024-11-08 Created: 2024-11-08 Last updated: 2024-11-13Bibliographically approved
List of papers
1. The transluminal attenuation gradient does not add diagnostic accuracy to coronary computed tomography
Open this publication in new window or tab >>The transluminal attenuation gradient does not add diagnostic accuracy to coronary computed tomography
Show others...
2021 (English)In: Acta Radiologica, ISSN 0284-1851, E-ISSN 1600-0455, p. 867-874Article in journal (Refereed) Published
Abstract [en]

Background A method for improving the accuracy of coronary computed tomography angiography (CCTA) is highly sought after as it would help to avoid unnecessary invasive coronary angiographies. Measurement of the transluminal attenuation gradient (TAG) has been proposed as an alternative to other existing methods, i.e. CT perfusion and CT fractional flow reserve (FFR). Purpose To evaluate the incremental value of three types of TAG in high-pitch spiral CCTA with invasive FFR measurements as reference. Material and Methods TAG was measured using two semi-automatic methods and one manual method. A receiver operating characteristic (ROC) analysis was made to determine the usefulness of TAG alone as well as TAG combined with CCTA for detection of significant coronary artery stenoses defined by an invasive FFR value <= 0.80. Results A total of 51 coronary vessels in 37 patients were included in this retrospective study. Hemodynamically significant stenoses were found in 13 vessels according to FFR. The ROC analysis TAG alone resulted in areas under the curve (AUCs) of 0.530 and 0.520 for the semi-automatic TAG and 0.557 for the manual TAG. TAG and CCTA combined resulted in AUCs of 0.567, 0.562 for semi-automatic TAG, and 0.569 for the manual TAG. Conclusion The results from our study showed no incremental value of TAG measured in single heartbeat CCTA in determining the severity of coronary artery stenosis degrees.

Place, publisher, year, edition, pages
Sage Publications, 2021
Keywords
Computed tomography angiography; coronary arteries; transluminal attenuation gradient; stenosis evaluation
National Category
Medical Imaging
Identifiers
urn:nbn:se:liu:diva-168541 (URN)10.1177/0284185120943042 (DOI)000554076900001 ()32722968 (PubMedID)2-s2.0-85088824098 (Scopus ID)
Available from: 2020-08-26 Created: 2020-08-26 Last updated: 2025-02-09Bibliographically approved
2. Evaluation of an AI-based, automatic coronary artery calcium scoring software
Open this publication in new window or tab >>Evaluation of an AI-based, automatic coronary artery calcium scoring software
Show others...
2020 (English)In: European Radiology, ISSN 0938-7994, E-ISSN 1432-1084, Vol. 30, no 3, p. 1671-1678Article in journal (Refereed) Published
Abstract [en]

Objectives

To evaluate an artificial intelligence (AI)–based, automatic coronary artery calcium (CAC) scoring software, using a semi-automatic software as a reference.

Methods

This observational study included 315 consecutive, non-contrast-enhanced calcium scoring computed tomography (CSCT) scans. A semi-automatic and an automatic software obtained the Agatston score (AS), the volume score (VS), the mass score (MS), and the number of calcified coronary lesions. Semi-automatic and automatic analysis time were registered, including a manual double-check of the automatic results. Statistical analyses were Spearman’s rank correlation coefficient (⍴), intra-class correlation (ICC), Bland Altman plots, weighted kappa analysis (κ), and Wilcoxon signed-rank test.

Results

The correlation and agreement for the AS, VS, and MS were ⍴ = 0.935, 0.932, 0.934 (p < 0.001), and ICC = 0.996, 0.996, 0.991, respectively (p < 0.001). The correlation and agreement for the number of calcified lesions were ⍴ = 0.903 and ICC = 0.977 (p < 0.001), respectively. The Bland Altman mean difference and 1.96 SD upper and lower limits of agreements for the AS, VS, and MS were − 8.2 (− 115.1 to 98.2), − 7.4 (− 93.9 to 79.1), and − 3.8 (− 33.6 to 25.9), respectively. Agreement in risk category assignment was 89.5% and κ = 0.919 (p < 0.001). The median time for the semi-automatic and automatic method was 59 s (IQR 35–100) and 36 s (IQR 29–49), respectively (p < 0.001).

Conclusions

There was an excellent correlation and agreement between the automatic software and the semi-automatic software for three CAC scores and the number of calcified lesions. Risk category classification was accurate but showing an overestimation bias tendency. Also, the automatic method was less time-demanding.

Key Points

• Coronary artery calcium (CAC) scoring is an excellent candidate for artificial intelligence (AI) development in a clinical setting.

• An AI-based, automatic software obtained CAC scores with excellent correlation and agreement compared with a conventional method but was less time-consuming.

Place, publisher, year, edition, pages
Springer, 2020
Keywords
Artificial intelligence; Software; Coronary artery disease; Multidetector computed tomography
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
urn:nbn:se:liu:diva-164650 (URN)10.1007/s00330-019-06489-x (DOI)000517458800042 ()31728692 (PubMedID)2-s2.0-85075234934 (Scopus ID)
Available from: 2020-03-29 Created: 2020-03-29 Last updated: 2024-11-08Bibliographically approved
3. Comparison of the Agatston score acquired with photon-counting detector CT and energy-integrating detector CT: ex vivo study of cadaveric hearts
Open this publication in new window or tab >>Comparison of the Agatston score acquired with photon-counting detector CT and energy-integrating detector CT: ex vivo study of cadaveric hearts
Show others...
2022 (English)In: The International Journal of Cardiovascular Imaging, ISSN 1569-5794, E-ISSN 1875-8312, Vol. 38, no 5, p. 1145-1155Article in journal (Refereed) Published
Abstract [en]

The purpose of this study was to compare the correlation and agreement between AS derived from either an energy-integrating detector CT (EID-CT) or a photon-counting detector CT (PCD-CT). Reproducibility was also compared. In total, 26 calcified coronary lesions (from five cadaveric hearts) were identified for inclusion. The hearts were positioned in a chest phantom and scanned in both an EID-CT and a prototype PCD-CT. The EID-CT and PCD-CT acquisition and reconstruction parameters were matched. To evaluate the reproducibility, the phantom was manually repositioned, and an additional scan was performed using both methods. The EID-CT reconstructions were performed using the dedicated calcium score kernel Sa36. The PCD-CT reconstructions were performed with a vendor-recommended kernel (Qr36). Several monoenergetic energy levels (50-150 keV) were evaluated to find the closest match with the EID-CT scans. A semi-automatic evaluation of calcium score was performed on a post-processing multimodality workplace. The best match with Sa36 was PCD-CT Qr36 images, at a monoenergetic level of 72 keV. Statistical analyses showed excellent correlation and agreement. The correlation and agreement with regards to the Agatston score (AS) between the two methods, for each position as well as between the two positions for each method, were assessed with the Spearman s rank correlation. The correlation coefficient, rho, was 0.98 and 0.97 respectively 0.99 and 0.98. The corresponding agreements were investigated by means of Bland-Altman plots. High correlation and agreement was observed between the AS derived from the EID-CT and a PCD-CT. Both methods also demonstrated excellent reproducibility.

Place, publisher, year, edition, pages
Springer, 2022
Keywords
Photon counting detector CT; CT-angiography; Heart; Arteriosclerosis; Calcium; Coronary vessels
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
urn:nbn:se:liu:diva-182359 (URN)10.1007/s10554-021-02494-8 (DOI)000739258200001 ()34988781 (PubMedID)2-s2.0-85122403893 (Scopus ID)
Note

Funding Agencies|Linkoping University; ALF Grants, Region Ostergotland [LIO 899441]

Available from: 2022-01-19 Created: 2022-01-19 Last updated: 2026-02-25Bibliographically approved
4. Automated AI-based coronary calcium scoring using retrospective CT data from SCAPIS is accurate and correlates with expert scoring
Open this publication in new window or tab >>Automated AI-based coronary calcium scoring using retrospective CT data from SCAPIS is accurate and correlates with expert scoring
2025 (English)In: European Radiology, ISSN 0938-7994, E-ISSN 1432-1084, Vol. 35, p. 2438-2447Article in journal (Refereed) Published
Abstract [en]

Objectives Evaluation of the correlation and agreement between AI and semi-automatic evaluations of calcium scoring CT (CSCT) examinations using extensive data from the Swedish CardioPulmonary bio-Image study (SCAPIS). Materials and methods&lt;bold&gt; &lt;/bold&gt;In total, 5057 CSCT examinations were performed on one CT system at Link & ouml;ping University Hospital between October 8, 2015, and June 12, 2018. AI evaluations were compared to semi-automatic CSCT results from expert reader evaluations rendered within SCAPIS. Pearson correlation, intraclass correlation coefficients (ICC), and Bland-Altman analysis were applied for Agatston (AS), volume (VS), mass scores (MS), number of lesions and lesion location. Agreement of Agatston score classifications into cardiovascular (CV) risk categories was evaluated with weighted kappa analysis. Results The evaluation included 4567 subjects, 2229 (48.8%) male, 2338 (51.2%) female, 50-64 years of age (mean 57.3 +/- 4.4). The AS ranged from 0 to 2871 in the cohort, with 2846 subjects having an AS of 0. Mean and median AS were 51.4 and 0.0, respectively. Total AS, VS, MS and number of lesions ICCs were 0.994, 0.994, 0.994, 0.960 (p &lt; 0.001), respectively. Bland-Altman analyses rendered mean differences +/- 1.96 SD upper and lower limits of agreement for AS -0.04, -52.5 to 52.4, VS -0.44, -46.51 to 45.63, and MS -0.07, -9.62 to 9.48. Weighted kappa analysis for CV risk category classifications was 0.913, and overall accuracy was 91.2%. Conclusion There was excellent correlation and agreement between AI and semi-automatic evaluations for all calcium scores, number of lesions and lesion location. High degrees of agreement and accuracy were found for the CV risk categorization.

Place, publisher, year, edition, pages
SPRINGER, 2025
Keywords
Coronary artery disease; Tomography (X-ray computed); Artificial intelligence
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
urn:nbn:se:liu:diva-209084 (URN)10.1007/s00330-024-11118-3 (DOI)001338124800001 ()39419864 (PubMedID)
Note

Funding Agencies|Local Research and Development Council in Ostergoetl; Swedish state [ROE-991454]; Linkoeping University

Available from: 2024-11-05 Created: 2024-11-05 Last updated: 2025-04-30

Open Access in DiVA

fulltext(4824 kB)623 downloads
File information
File name FULLTEXT01.pdfFile size 4824 kBChecksum SHA-512
19a192ac6685343afb7c6d50418dcabbcb9f22917d3dc257be7859fc693349544335a235f405064c3628fb31ff74134d1544bb8a12116d898b3d0df4c72976e5
Type fulltextMimetype application/pdf
Order online >>

Other links

Publisher's full text

Authority records

Henriksson, Lilian

Search in DiVA

By author/editor
Henriksson, Lilian
By organisation
Division of Diagnostics and Specialist MedicineFaculty of Medicine and Health SciencesDepartment of Radiology in Linköping
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar
Total: 633 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
isbn
urn-nbn

Altmetric score

doi
isbn
urn-nbn
Total: 1674 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf