liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Artificial neural networks trained on simulated multispectral data for real-time imaging of skin microcirculatory blood oxygen saturation
Linköping University, Department of Biomedical Engineering, Division of Biomedical Engineering. Linköping University, Faculty of Science & Engineering.ORCID iD: 0000-0001-6385-6760
Linköping University, Department of Health, Medicine and Caring Sciences, Division of Diagnostics and Specialist Medicine. Linköping University, Faculty of Medicine and Health Sciences.ORCID iD: 0000-0001-8128-871X
Linköping University, Department of Biomedical Engineering, Division of Biomedical Engineering. Linköping University, Faculty of Science & Engineering.ORCID iD: 0000-0002-0246-2490
Linköping University, Department of Biomedical Engineering, Division of Biomedical Engineering. Linköping University, Faculty of Science & Engineering.ORCID iD: 0000-0002-7299-891X
Show others and affiliations
2024 (English)In: Journal of Biomedical Optics, ISSN 1083-3668, E-ISSN 1560-2281, Vol. 29, article id S33304Article in journal (Refereed) Published
Abstract [en]

Significance Imaging blood oxygen saturation (SO2) in the skin can be of clinical value when studying ischemic tissue. Emerging multispectral snapshot cameras enable real-time imaging but are limited by slow analysis when using inverse Monte Carlo (MC), the gold standard for analyzing multispectral data. Using artificial neural networks (ANNs) facilitates a significantly faster analysis but requires a large amount of high-quality training data from a wide range of tissue types for a precise estimation of SO2. Aim We aim to develop a framework for training ANNs that estimates SO2 in real time from multispectral data with a precision comparable to inverse MC. Approach ANNs are trained using synthetic data from a model that includes MC simulations of light propagation in tissue and hardware characteristics. The model includes physiologically relevant variations in optical properties, unique sensor characteristics, variations in illumination spectrum, and detector noise. This approach enables a rapid way of generating high-quality training data that covers different tissue types and skin pigmentation. Results The ANN implementation analyzes an image in 0.11 s, which is at least 10,000 times faster than inverse MC. The hardware modeling is significantly improved by an in-house calibration of the sensor spectral response. An in-vivo example shows that inverse MC and ANN give almost identical SO2 values with a mean absolute deviation of 1.3%-units. Conclusions ANN can replace inverse MC and enable real-time imaging of microcirculatory SO2 in the skin if detailed and precise modeling of both tissue and hardware is used when generating training data.

Place, publisher, year, edition, pages
SPIE-SOC PHOTO-OPTICAL INSTRUMENTATION ENGINEERS , 2024. Vol. 29, article id S33304
Keywords [en]
multispectral imaging; blood oxygen saturation; microcirculation; artificial neural networks; Monte Carlo simulation
National Category
Medical Laboratory Technologies
Identifiers
URN: urn:nbn:se:liu:diva-211079DOI: 10.1117/1.JBO.29.S3.S33304ISI: 001391715700010PubMedID: 38989257Scopus ID: 2-s2.0-85198476458OAI: oai:DiVA.org:liu-211079DiVA, id: diva2:1929888
Note

Funding Agencies|Swedish Research Council; Sweden's Innovation Agency VINNOVA [2017-01435, 2019-01522]; [2014-6141]

Available from: 2025-01-21 Created: 2025-01-21 Last updated: 2025-05-14

Open Access in DiVA

fulltext(3801 kB)66 downloads
File information
File name FULLTEXT01.pdfFile size 3801 kBChecksum SHA-512
0d33593226ee0fd126849842a26da34407cef0e8fe194ee591e46dfa6f004416cabe914f8f9a405ce24c18241ef3a0bd96a782758cab9932404488c480e254f0
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMedScopus

Search in DiVA

By author/editor
Larsson, MarcusEwerlöf, MariaSalerud, GöranStrömberg, TomasFredriksson, Ingemar
By organisation
Division of Biomedical EngineeringFaculty of Science & EngineeringDivision of Diagnostics and Specialist MedicineFaculty of Medicine and Health Sciences
In the same journal
Journal of Biomedical Optics
Medical Laboratory Technologies

Search outside of DiVA

GoogleGoogle Scholar
Total: 66 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 146 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf