Spectral Computed Tomography of the Injured Knee
Linköping University, Department of Health, Medicine and Caring Sciences, Division of Diagnostics and Specialist Medicine. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Center for Diagnostics, Department of Radiology in Linköping.ORCID iD: 0000-0002-7077-5667
2025 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Computed tomography (CT) is widely used for fracture detection and postsurgical evaluation. Recent advancements have opened new possibilities, particularly in spectral CT, which utilises the energy-dependant attenuation properties of tissues to enable tissue differentiation and enhance diagnostic capabilities. The two primary techniques employed in spectral CT are Dual-energy CT (DECT) and, more recently, photon-counting detector CT (PCD-CT). The overall aim of this thesis is to investigate the use of spectral CT for improved imaging of the injured knee.

In Study I, the diagnostic accuracy of DECT for detecting bone marrow lesions (BMLs) in patients with suspected anterior cruciate ligament (ACL) injury was assessed. BMLs, commonly observed on MRI as a result of bone contusions, provide insights into trauma mechanisms and associated injuries. In standard CT, the attenuation differences corresponding to these lesions are obscured by overlying bone. DECT overcomes this, generating virtual non-calcium (VNCa) images as colour overlays on the CT images. DECT knee images from 48 patients were evaluated for the presence and size of BMLs by two readers. Consensus MRI served as the reference standard. The diagnostic accuracy was moderate with 70.1 % (95% CI 63.3-76.2) and 69.1% (95% CI 61.7-75.9) overall sensitivity and specificity, moderate to substantial intrareader agreement and fair to moderate interreader agreement. Lesion volumes were comparable in the femur but underestimated in the tibia.

Study II evaluated the diagnostic accuracy of DECT and MRI for detecting ACL injuries. The ACL, being an important stabilising structure of the knee, is typically imaged using MRI. The diagnostic performance of DECT and MRI was evaluated, with arthroscopy serving as the reference standard. From the cohort in Study I, arthroscopy data was available for 21 patients who were included in the analysis. The combined sensitivity across all four readings for DECT was 76.3 % (95% CI 66.8-85.9), which was lower than that of MRI at 86.8% (95% CI 71.9-95.6). Both methods demonstrated high positive predictive values: 93.6% (95% CI 84.3-98.2) for DECT and 91.7% (95% CI 77.5-98.3) for MRI.

In Study III, a PCD-CT prototype was evaluated using a bovine knee specimen with an induced fracture and metallic osteosynthesis material. Virtual monoenergetic images (VMI) generated by the PCD-CT at 120 kV and 140 kV tube potentials were compared to conventional energy-integrating detector CT (EID-CT) images acquired with dual- and single-energy, both with and without iterative metal artefact reduction algorithm (iMAR). Four readers assessed image quality with respect to metal artefacts. PCD-CT 140 kV VMI at 150 keV received the highest scores and was significantly superior to single-energy Sn150 kV images with iMAR. While DECT iMAR images scored lower than PCD-CT images, the difference was not statistically significant. Image quality scores were also significantly lower for 120 kV tube potential and lower VMI values at 72 keV.

Study IV explored the metal artefact reduction capabilities of a commercially available PCD-CT in twelve patients with surgically treated tibial plateau fractures. PCD-CT 140 kV ultra-high resolution (UHR) scans were reconstructed as VMI at 70, 110 and 150 keV, using smooth and sharp kernels, with and without iMAR, as well as polychromatic images with an extra-sharp kernel. EID-CT Sn150 kV scans were reconstructed with smooth and sharp kernels, with and without iMAR. Five readers assessed the image quality. EID-CT iMAR images scored significantly higher for reducing metal artefact streaks, whereas bone-metal interface visualisation was comparable between PCD-CT high VMI and EID-CT with IMAR. PCD-CT with an extra sharp kernel was superior for bone visualisation.

Abstract [sv]

Datortomografi (DT) en allmänt använd metod för frakturdiagnostik och för postoperativ utvärdering. De senaste framstegen inom DT-tekniken har öppnat nya möjligheter, särskilt inom spektral DT, där vävnadernas energiberoende attenueringsegenskaper nyttjas för att förbättrad vävnadsurskiljning och skapa nya diagnostiska möjligheter. Spektral DT kan baseras på två huvudsakliga tekniker: dubbelenergi-DT (dual-energy computed tomography (DECT)) och den nyare fotonräknande datortomografen (photon-counting detector computed tomography (PCD-CT)). Det övergripande syftet med denna avhandling var att undersökta användningen av spektral DT för förbättrad bilddiagnostik av knäskador.

I Studie I utvärderades den diagnostiska noggrannheten för DECT vid detektion av benmärgslesioner (BML) hos patienter med misstänkt främre korsbandsskada. BML, ett vanligt fynd vid MRT efter benkontusioner, kan ge information om traumamekanism och associerade skador. På konventionella DT-bilder döljs ofta de små attenueringsskillnaderna, associerade med BML, av de mellanliggande bentrabeklerna, men med DECT kan virtuella bilder utan calcium skapas och förbättra synligheten av BML. DECT-bilder av knän från 48 patienter utvärderades av två bedömare avseende förekomst av och storlek på BML. Konsensusbedömningen av MRT bilderna utgjorde referensmetod. Den diagnostisk tillförlitligheten var måttlig med övergripande sensitivitet och specificitet på 70,1% (95% (KI) 63,3–76,2) respektive 69,1% (95% KI 61,7–75,9), måttlig till betydande intrabedömaröverensstämmelse och skaplig till måttlig överensstämmelse mellan bedömare. Den uppmätta volymen för lesioner i femur skilde sig marginellt åt mellan DECT och MRT, medan volymen underskattades med DECT för lesioner i tibia.

Studie II handlade diagnostisk tillförlitlighet avseende korsbandsskador. Det främre korsbandet, en viktig stabiliserande struktur i knäleden, avbildas vanligen med MRT. I Studie II användes artroskopi som referensmetod för att utvärdera den diagnostiska prestandan hos DECT och MRT avseende detektion av främre korsbandsskador. Från kohorten i Studie I, erhölls artroskopidata för 21 patienter, vilka kunde inkluderas i analysen. Den kombinerade sensitiviteten från alla fyra granskningarna av DECT-bilderna var 76,3 % (95% KI 66,8–85,9), vilket var lägre än för MRT, där sensitiviteten var 86,8% (95% KI 71.9–95.6). Båda metoderna uppvisade höga positiva prediktiva värden: 93,6% (95% KI 84,3–98,2) för DECT och 91,7% (95% KI 77,5–98,3) för MRT.

I Studie III utvärderades en PCD-CT-prototyp med hjälp av ett knäpreparat från ko med en fraktur och metalliskt osteosyntesmaterial. Virtuellt monoenergetiska (VMI) genererade med 120 kV respektive 140 kV rörspänning jämfördes mot bilder från en konventionell DT med energiintegrerande detektor (energy-integrating detector computed tomography (EID-CT)), erhållna med dubbelenergi (DECT) respektive enkelenergi, både utan och med metallartefaktreducerande algoritm (iMAR). Fyra bedömare utvärderade bildkvaliteten avseende metallartefakter. PCD-CT 140 kV VMI på 150 keV skattades högst och skillnaden mot skattningen av enkelenergibilderna erhållna med 150 kV och tennfiltrering samt iMAR var statistiskt signifikant. DECT bilder med iMAR skattades lägre än nämnda PCD-CT-bilder, men skillnaden var inte signifikant. Även skattningen av PCD-CT-bilder erhållna med 120 kV och de som rekonstruerats som VMI 72 keV var signifikant lägre.

I Studie IV undersöktes de metallartefaktreducerande förmågorna hos en kommersiellt tillgänglig PCD-CT för bilder av tolv patienter med operativt åtgärdad tibiaplatåfraktur. PCD-CT-bilder skapade med 140 kV rörspänning och ultrahög upplösning (ultra-high resolution, UHR) rekonstruerades som VMI på 70, 110 och 150 keV, med både mjuk och hård kernel, samt utan och med iMAR. Fem granskare bedömde bildkvaliteten. EID-CT med iMAR erhöll signifikant högre skattning för reduktion av metallartefaktsstråk, medan benmetall- gränsen visualiserades likartat mellan PCD-CT med hög VMI och EIDCT med iMAR. PCD-CT extra hård kernel uppvisade bäst kvalitet för visualisering av ben.

Place, publisher, year, edition, pages
Linköping: Linköping University Electronic Press, 2025. , p. 95
Series
Linköping University Medical Dissertations, ISSN 0345-0082 ; 1957
Keywords [en]
Computed Tomography, Dual-Energy CT, Photon-Counting CT, Musculoskeletal imaging, Trauma, Bone marrow lesion, Anterior cruciate ligament, Tibial plateau fracture, Metal artefacts
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
URN: urn:nbn:se:liu:diva-211352DOI: 10.3384/9789180759267ISBN: 9789180759250 (print)ISBN: 9789180759267 (electronic)OAI: oai:DiVA.org:liu-211352DiVA, id: diva2:1934543
Public defence
2025-03-07, Belladonna, Building 511, Campus US, Linköping, 09:00 (Swedish)
Opponent
Supervisors
Available from: 2025-02-04 Created: 2025-02-04 Last updated: 2026-09-22Bibliographically approved
List of papers
1. Diagnostic accuracy of dual-energy CT for detection of bone marrow lesions in the subacutely injured knee with MRI as reference method
Open this publication in new window or tab >>Diagnostic accuracy of dual-energy CT for detection of bone marrow lesions in the subacutely injured knee with MRI as reference method
2020 (English)In: Acta Radiologica, ISSN 0284-1851, E-ISSN 1600-0455, Vol. 61, no 6, p. 749-759Article in journal (Refereed) Published
Abstract [en]

Background Dual-energy computer tomography (DECT) can detect post-traumatic bone marrow lesions. Prospective studies of the knee with large numbers of participants and intra-observer agreement assessment are limited. Purpose To investigate the diagnostic accuracy of DECT in detecting bone marrow lesions as well as estimating the bone marrow lesion volume in patients with suspected anterior cruciate ligament trauma with magnetic resonance imaging (MRI) as reference standard. Material and Methods Forty-eight consecutive patients with suspected anterior cruciate ligament injury were imaged bilaterally with DECT within a mean of 25 days (range 4-55 days) following injury and MRI within seven days of DECT. Two readers analyzed DECT virtual non-calcium-blinded images. Consensus MRI was reference standard. Intra- and inter-observer agreement were determined using weighted kappa statistics. Sensitivity, specificity, and negative and positive predictive values were calculated. Bone marrow lesion volumes were measured; for comparison, intra-class correlation coefficient was used. Results The 48 patients (26 men, 22 women; mean age 23 years, age range 15-37 years) were imaged bilaterally yielding 52 knees with bone marrow lesions, of which 44 were in the femur and 41 were in the tibia. Intra- and inter-observer agreement to detect bone marrow lesions was moderate and fair to moderate (kappa 0.54-0.66, 95% confidence interval [CI] 0.39-0.80 and 0.37-0.41, 95% CI 0.20-0.57) and overall sensitivity and specificity were 70.1% and 69.1%, respectively. Positive and negative predictive values were 72.9% and 66.1%, respectively. Bone marrow lesion volumes showed excellent intra- and inter-observer agreement (0.83-0.91, 95% CI 0.74-0.94 and 0.76-0.78, 95% CI 0.57-0.87). Conclusion The diagnostic performance of DECT to detect bone marrow lesions in the subacutely injured knee was moderate with intra- and inter-observer agreement ranging from moderate to substantial and fair to moderate. Bone marrow lesion volume correlation was excellent.

Place, publisher, year, edition, pages
SAGE PUBLICATIONS LTD, 2020
Keywords
Knee; dual-energy computed tomography; trauma; bone marrow lesion
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
urn:nbn:se:liu:diva-161616 (URN)10.1177/0284185119877343 (DOI)000491671400001 ()31581782 (PubMedID)
Note

Funding Agencies|Swedish Medical Research CouncilSwedish Medical Research Council (SMRC) [VR 2015-03687]; Division of Radiological Sciences, Department of Medical and Health Sciences, Faculty of Health Sciences, Link_oping University

Available from: 2019-11-05 Created: 2019-11-05 Last updated: 2025-02-04
2. Sensitivity of DECT in ACL tears. A prospective study with arthroscopy as reference method
Open this publication in new window or tab >>Sensitivity of DECT in ACL tears. A prospective study with arthroscopy as reference method
2022 (English)In: Acta Radiologica Open, E-ISSN 2058-4601, Vol. 11, no 3Article in journal (Refereed) Published
Abstract [en]

Background: CT is often used for fracture evaluation following knee trauma and to diagnose ACL injuries would also be valuable. Purpose: To investigate the diagnostic accuracy of dual energy CT (DECT) for detection of ACL tears in acute and subacute knee injuries. Material and Methods: Patients with suspected ACL injury were imaged with DECT and MRI. Clinically blinded DECT images were independently read twice by two radiologists. ACL was classified as normal or abnormal. Arthroscopy served as reference method. Sensitivity and positive predictive value (PPV) were calculated, and diagnostic performance between DECT and MRI was assessed. Results: 48 patients (26 M, 22 F, mean age 23 years, range 15-37 years) were imaged with a mean of 25 days following trauma. Of these, 21 patients underwent arthroscopy with a mean of 195 days after trauma. Arthroscopy revealed 19 ACL tears and 2 ACLs with no tear. The combined sensitivity was 76.3% (95% CI 66.8-85.9) and 86.8 (95% CI 71.9-95.6) for DECT and MRI, respectively. There was no statistically significant difference between these two methods (p = .223). The positive predictive value (PPV) was 93.5 (95% CI 84.3-98.2) and 91.7 (95% CI 77.5-98.3) for DECT and MRI, respectively. Conclusion: DECT has lower sensitivity to detect an ACL rupture than MRI, but the difference is not statistically significant. The PPV is high in both methods.

Place, publisher, year, edition, pages
Sage Publications, 2022
Keywords
Knee; ACL; trauma; dual energy CT; ligament tear
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
urn:nbn:se:liu:diva-184137 (URN)10.1177/20584601221075799 (DOI)000770911500001 ()35295865 (PubMedID)
Available from: 2022-04-08 Created: 2022-04-08 Last updated: 2025-02-04
3. Spectral photon-counting CT: Image quality evaluation using a metal-containing bovine bone specimen
Open this publication in new window or tab >>Spectral photon-counting CT: Image quality evaluation using a metal-containing bovine bone specimen
Show others...
2023 (English)In: European Journal of Radiology, ISSN 0720-048X, E-ISSN 1872-7727, Vol. 168, article id 111110Article in journal (Refereed) Published
Abstract [en]

Purpose: To find the optimal imaging parameters for a photon-counting detector CT (PCD-CT) and to compare it to an energy-integrating detector CT (EID-CT) in terms of image quality and metal artefact severity using a metal-containing bovine knee specimen. Methods: A bovine knee with a stainless-steel plate and screws was imaged in a whole-body research PCD-CT at 120 kV and 140 kV and in an EID dual-source CT (DSCT) at Sn150 kV and 80/Sn150 kV. PCD-CT virtual monoenergetic 72 and 150 keV images and EID-CT images processed with and without metal artefact reduction algorithms (iMAR) were compared. Four radiologists rated the visualisation of bony structures and metal artefact severity. The Friedman test and Wilcoxon signed-rank test with Bonferronis correction were used. P-values of <= 0.0001 were considered statistically significant. Distributions of HU values of regions of interest (ROIs) in artefact-affected areas were analysed.Results: PCD-CT 140 kV 150 keV images received the highest scores and were significantly better than EID-CT Sn150 kV images. PCD-CT 72 keV images were rated significantly lower than all the others. HU-value variation was larger in the 120 kV and the 72 keV images. The ROI analysis revealed no large difference between scanners regarding artefact severity.Conclusion: PCD-CT 140 kV 150 keV images of a metal-containing bovine knee specimen provided the best image quality. They were superior to, or as good as, the best EID-CT images; even without the presumed advantage of tin filter and metal artefact reduction algorithms. PCD-CT is a promising method for reducing metal artefacts.

Place, publisher, year, edition, pages
ELSEVIER IRELAND LTD, 2023
Keywords
PCD-CT; Musculoskeletal imaging; Image quality; Metal artefacts; Diagnostic imaging
National Category
Medical Imaging
Identifiers
urn:nbn:se:liu:diva-199134 (URN)10.1016/j.ejrad.2023.111110 (DOI)001087180300001 ()37788519 (PubMedID)
Note

Funding Agencies|ALF Grants [LIO-936128]; Centre for Diagnostics, Region Ostergotland

Available from: 2023-11-14 Created: 2023-11-14 Last updated: 2025-02-09
4. Photon-counting CT: image quality evaluation in patients with tibial plateau fracture treated with metallic osteosynthesis material
Open this publication in new window or tab >>Photon-counting CT: image quality evaluation in patients with tibial plateau fracture treated with metallic osteosynthesis material
Show others...
2026 (English)In: European Radiology Experimental, E-ISSN 2509-9280, Vol. 10, no 1, article id 96Article in journal (Refereed) Published
Abstract [en]

ObjectiveThe aim was to compare the image quality of photon-counting detector CT (PCD-CT) and energy-integrating detector CT (EID-CT) in patients with tibial plateau fractures treated with metallic osteosynthesis material, and to identify optimal reconstruction parameters for PCD-CT.Materials and methodsAfter ethical approval, twelve patients underwent PCD-CT and EID-CT scans. Images were reconstructed using bone and soft-tissue kernels with metal artifact reduction (iMAR). PCD-CT virtual monoenergetic images (VMI) at 70, 110, and 150 keV were generated. Five radiologists assessed metal artifact severity and bone and soft-tissue visualization using a 7-point Likert scale. Visual grading characteristics analysis was performed. Noise levels were quantified and compared using Wilcoxon's signed-rank test.ResultsEID-CT was rated superior in reducing metal-artifact streaks (AUC: 0.10-0.21). No significant difference was found between EID-CT iMAR and PCD-CT VMI at 110 keV and 150 keV (AUC: 0.40-0.49) concerning the metal-bone interface. An ultra-high-resolution PCD-CT kernel outperformed its EID-CT counterpart in bone visualization, with AUC values of 0.67-0.92 across all bone criteria, including those incorporating artifact-affected regions. PCD-CT showed lower noise.ConclusionMetal artifact reduction was superior in EID-CT iMAR images compared to PCD-CT iMAR and VMI 110/150 keV, except at the metal-bone interface, where EID-CT iMAR images and PCD-CT VMI 110/150 keV performed comparably. The ultra-high-resolution PCD-CT kernel provided the best bone visualization, even when artifact-affected areas were included. Noise levels were lower in PCD-CT. This is the first in vivo comparison of photon-counting and energy-integrating CT for postoperative knee imaging with metallic osteosynthesis material.Relevance statementThese findings highlight the need for improved metal artifact reduction in PCD-CT, while demonstrating superior bone visualization, and support a complementary interpretation strategy in postoperative knees using high-energy VMI and MAR-corrected reconstructions.Key pointsPhoton-counting CT demonstrated excellent bone visualization.Conventional EID-CT achieved better metal artifact reduction than photon-counting CT.The metal-bone interface was rated similarly for energy-integrating CT and photon-counting CT virtual monoenergetic images.These findings indicate that further improvements in metal artifact reduction algorithms for PCD-CT are warranted.

Place, publisher, year, edition, pages
SPRINGER WIEN, 2026
Keywords
Artifacts; Fracture fixation (internal); Fractures; Knee joint; Tomography (X-ray computed)
National Category
Medical Imaging
Identifiers
urn:nbn:se:liu:diva-225863 (URN)10.1186/s41747-026-00761-8 (DOI)001797844400002 ()42319599 (PubMedID)2-s2.0-105042251506 (Scopus ID)
Note

Funding Agencies|Region stergtland

Available from: 2026-06-30 Created: 2026-06-30 Last updated: 2026-09-22

Open Access in DiVA

fulltext(7795 kB)409 downloads
File information
File name FULLTEXT01.pdfFile size 7795 kBChecksum SHA-512
3e42a88f00f2aba637bb814bbbd06623a64ed47a7c7a27748ac8659aaad200bb97baab02d356d9ea756445c0a3c662a7df4074ee393c4bcd3d9c977ddbcb3efb
Type fulltextMimetype application/pdf
Order online >>

Other links

Publisher's full text

Authority records

Björkman, Ann-Sofi

Search in DiVA

By author/editor
Björkman, Ann-Sofi
By organisation
Division of Diagnostics and Specialist MedicineFaculty of Medicine and Health SciencesDepartment of Radiology in Linköping
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar
Total: 416 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
isbn
urn-nbn

Altmetric score

doi
isbn
urn-nbn
Total: 1690 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf