Sex and age-related day-to-day variability in the skin microcirculation during post-occlusive reactive hyperemiaShow others and affiliations
2025 (English)In: Microvascular Research, ISSN 0026-2862, E-ISSN 1095-9319, Vol. 159, article id 104783Article in journal (Refereed) Published
Abstract [en]
Introduction: Little is known about the day-to-day variability of different skin microcirculation parameters, and how this variability is influenced by age and sex. The aim was to examine the day-to-day variability of microcirculatory parameters in relation to age and sex. Methods: The cutaneous microcirculation was measured using a fiber optic probe integrating laser Doppler flowmetry (LDF) and diffuse reflectance spectroscopy (DRS) to measure oxygen saturation, red blood cell (RBC) tissue fraction, speed-resolved and conventional perfusion. Measurements at two separate days were compared during baseline, a 5-min occlusion and during the following post-occlusive reactive hyperemia (PORH) period on the volar forearm and dorsal foot in totally 48 men and women aged 20-30 and 50-60 years, respectively. Variability was expressed as the coefficient of variation CV and repeatability as the intraclass correlation coefficient ICC. Results: Peak oxygen saturation during PORH had the lowest day-to-day variability for the forearm (CV = 2.1 %) and the foot (CV = 3.8 %) as well as an excellent repeatability (ICC = 0.80 and ICC = 0.82, respectively). Older women had a higher day-to-day variability in baseline conventional perfusion compared to younger women on the forearm (p = 0.007). On the foot, older women had a lower day-to-day variability than younger women for baseline oxygen saturation (p = 0.006) and peak RBC tissue concentration (p = 0.008). Older men had a lower day-to-day variability than younger men for baseline oxygen saturation (p = 0.012) but a higher variability for baseline and peak RBC tissue concentration (p = 0.008 and p = 0.002) on the foot. Conclusion: Peak oxygen saturation had the lowest day-to-day variability of the measured parameters. A lower value of peak oxygen saturation has previously been associated with increasing systematic coronary risk implying that this is a suitable parameter for measuring microcirculatory dysfunction. Sex and age only affected the day-to-day variability of very few parameters.
Place, publisher, year, edition, pages
ACADEMIC PRESS INC ELSEVIER SCIENCE , 2025. Vol. 159, article id 104783
Keywords [en]
Skin; Microcirculation; Laser doppler flowmetry; Diffuse reflectance spectroscopy; Variability
National Category
Medical Laboratory Technologies
Identifiers
URN: urn:nbn:se:liu:diva-211564DOI: 10.1016/j.mvr.2025.104783ISI: 001409803400001PubMedID: 39837458Scopus ID: 2-s2.0-85215832892OAI: oai:DiVA.org:liu-211564DiVA, id: diva2:1936256
Note
Funding Agencies|ALF grants, Region Ostergotland, Linkoping, Sweden [RO-973413, RO-985791]; Knut and Alice Wallenberg Foundation