liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Assessment of bone-implant interface image quality for in-vivo acetabular cup implants using photon-counting detector CT: Impact of tin pre-filtration
Linköping University, Department of Health, Medicine and Caring Sciences, Division of Diagnostics and Specialist Medicine. Linköping University, Faculty of Medicine and Health Sciences. Linköping University, Center for Medical Image Science and Visualization (CMIV). Erasmus MC, Netherlands.ORCID iD: 0000-0002-0589-1346
Erasmus MC, Netherlands.
Linköping University, Department of Health, Medicine and Caring Sciences, Division of Diagnostics and Specialist Medicine. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Center for Diagnostics, Medical radiation physics. Linköping University, Center for Medical Image Science and Visualization (CMIV).ORCID iD: 0000-0002-8387-0583
Linköping University, Department of Health, Medicine and Caring Sciences, Division of Diagnostics and Specialist Medicine. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Center for Diagnostics, Department of Radiology in Linköping. Linköping University, Center for Medical Image Science and Visualization (CMIV).ORCID iD: 0000-0003-0066-4985
Show others and affiliations
2025 (English)In: European Journal of Radiology Open, E-ISSN 2352-0477, Vol. 14, article id 100646Article in journal (Refereed) Published
Abstract [en]

Purpose: To assess the image quality of the bone-implant interface of acetabular cup implants using photon-counting detector (PCD) CT with and without tin pre-filtration in a clinical setting. Methods and materials: Twenty-four patients underwent PCD-CT imaging of their total hip replacement (THR). Twelve patients were scanned using 140 kVp and twelve patients using 140 kVp with tin pre-filtration (Sn140 kVp). All scans were acquired with a collimation of 120 x 0.2 mm. The acquired data was reconstructed with different slice thickness (0.2 mm-0.6 mm) and kernel (Qr) strengths (56, 76, 89) with and without metal artifact reduction (iMAR). Two observers assessed the image quality of the bone-implant interface for the cup based on four image quality criteria. Bone contrast, contrast-to-noise ratio (CNR) of bone/fat and cortical sharpness was performed as quantitative measures. Results: Image quality was rated highest for 0.2 mm slice thickness and Qr89 kernel across all four criteria for both the 140 kVp and Sn140 kVp by both observers, with a slight preference for the Sn140kVp over the 140 kVp. In all cases and for all image criteria the 0.2 mm/Qr89 was preferred above the Qr76 and Qr56/iMAR for both the 140 kVp and Sn140 kVp by both observers. Quantitative measurements confirmed significantly improved bone contrast as well as cortical sharpness using 0.2 mm/Qr89. Tin pre-filtration did not affect the CNR at 0.2 mm/Qr89 but tended to decrease cortical sharpness. Conclusions: High resolution PCD-CT allows for in-vivo assessment of the bone-implant interface in patients with THR and is preferably acquired with tin pre-filtration.

Place, publisher, year, edition, pages
ELSEVIER , 2025. Vol. 14, article id 100646
Keywords [en]
Arthroplasty; Image quality; Orthopedic Implants; Osseointegration; Photon-counting detector CT
National Category
Radiology and Medical Imaging
Identifiers
URN: urn:nbn:se:liu:diva-212998DOI: 10.1016/j.ejro.2025.100646ISI: 001459513100001Scopus ID: 2-s2.0-105000951922OAI: oai:DiVA.org:liu-212998DiVA, id: diva2:1952256
Available from: 2025-04-15 Created: 2025-04-15 Last updated: 2025-05-23

Open Access in DiVA

fulltext(1513 kB)62 downloads
File information
File name FULLTEXT01.pdfFile size 1513 kBChecksum SHA-512
dcccd81074080ef92eec2b9f64dfd503de85d3326d18dbeb6a86e300486dcafe0523f88596af444f4a5c186faa53f9af2356f3de4c85362e99d17386e3d01530
Type fulltextMimetype application/pdf

Other links

Publisher's full textScopus

Search in DiVA

By author/editor
Booij, RonaldTesselaar, ErikWoisetschläger, MischaSchilcher, Jörg
By organisation
Division of Diagnostics and Specialist MedicineFaculty of Medicine and Health SciencesCenter for Medical Image Science and Visualization (CMIV)Medical radiation physicsDepartment of Radiology in LinköpingDivision of Surgery, Orthopedics and OncologyDepartment of Orthopaedics in Linköping
In the same journal
European Journal of Radiology Open
Radiology and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar
Total: 63 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 108 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf