liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Can we trust naked eye assessments of the capillary refill test in children? An experimental study
Linköping University, Department of Biomedical and Clinical Sciences, Division of Clinical Chemistry and Pharmacology. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Local Health Care Services in Central Östergötland, Department of Emergency Medicine in Linköping.
Linköping University, Department of Biomedical and Clinical Sciences. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Center of Paediatrics and Gynaecology and Obstetrics, H.K.H. Kronprinsessan Victorias barn- och ungdomssjukhus.
Linköping University, Department of Biomedical and Clinical Sciences, Division of Clinical Chemistry and Pharmacology. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Local Health Care Services in Central Östergötland, Department of Emergency Medicine in Linköping.ORCID iD: 0000-0001-5281-9438
Linköping University, Department of Biomedical and Clinical Sciences, Division of Clinical Chemistry and Pharmacology. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Local Health Care Services in Central Östergötland, Department of Emergency Medicine in Linköping.ORCID iD: 0000-0001-6347-3970
2025 (English)In: BMC Emergency Medicine, E-ISSN 1471-227X, Vol. 25, no 1, article id 48Article in journal (Refereed) Published
Abstract [en]

BackgroundThe capillary refill test is widely used in pediatric emergency medicine and critical care although its validity and reliability are debated. Naked eye estimation is the recommended method for capillary refill time (CR time) assessment. The goal of this study was to compare naked eye estimations of the CR time in pediatric patients to quantified capillary refill time (qCR time) using polarized reflectance imaging as an objective reference, and to investigate interobserver and intra-observer consistency of naked eye assessments of CR time.MethodA film sequence comprising videos of capillary refill tests from 15 emergency pediatric patients was shown under standardized conditions to 62 observers (pediatricians, nurses, assistant nurses, and medical secretaries). The observers' estimations of CR time in seconds and in descriptive categorizations were compared to objectively derived qCR time. Three tests were shown twice without the observers' knowledge.ResultsThere was poor interobserver agreement in all professions, with limits of agreement ranging from 1.17 s (assistant nurses) to 2.00 s (secretaries). Intra-observer agreement for estimations of both time and descriptive categorizations was limited. The correlation between naked eye assessments and qCR time was weak.ConclusionThis study shows that naked eye assessment of CR time in children is highly subjective with poor reproducibility in pediatric nurses and pediatricians, as well as in comparison to a quantitative method. Based on the lack of both inter- and intra-observer consistency in the assessments, these findings suggest that CR time assessed by naked eye should be questioned as a routine test in pediatric emergencies.

Place, publisher, year, edition, pages
BMC , 2025. Vol. 25, no 1, article id 48
Keywords [en]
Capillary refill; Emergency care; Pediatrics; Microcirculation
National Category
Health Care Service and Management, Health Policy and Services and Health Economy
Identifiers
URN: urn:nbn:se:liu:diva-213039DOI: 10.1186/s12873-025-01204-0ISI: 001454770500001PubMedID: 40155796Scopus ID: 2-s2.0-105001406089OAI: oai:DiVA.org:liu-213039DiVA, id: diva2:1952841
Note

Funding Agencies|Linkoping University; Region Ostergoetland [LIO-532001, LIO-700271]; Wallenberg Center of Molecular Medicine at Linkoping University

Available from: 2025-04-16 Created: 2025-04-16 Last updated: 2025-12-15
In thesis
1. Under Pressure: Microcirculatory Dynamics and Capillary Refill Assessment in Provocation and Hemodynamic Stress
Open this publication in new window or tab >>Under Pressure: Microcirculatory Dynamics and Capillary Refill Assessment in Provocation and Hemodynamic Stress
2026 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Background: All patients seeking emergency care or admitted to hospital need to be assessed and often monitored over a period. Vital functions are assessed at the bedside with technical equipment and clinical judgement. A commonly performed test, the capillary refill test (CRtest), is supposed to assess circulatory function. The test is performed by pressing the examiners’ index finger onto the patient skin, often for 5 seconds, then rapidly remove the finger and watch the skin regain its original colour as it was before the blanching pressure was applied. The time it takes is called the capillary refill time (CRtime) and less than 2-3 seconds have been recommended as normal, and times longer than that as a sign of circulatory compromise. The CRtest, despite widely used, has been questioned due to its subjectivity, and uncertainty of the test’s external validity.

Objectives: The purpose of the study in Paper I was to investigate the repeatability of the CRtest, In Paper II, inter- and intra-observer reliability of the test was investigated, In Paper III, the outcome of the test in a blood loss shock model was investigated. The relationship between the changes in microcirculation to the CRtime in a blood loss shock model was investigated in Paper IV.

Methods: In Paper I, CRtests were performed on study subjects on the sternum, the forehead and the finger, in series of 2 and 5 minutes apart. Objectively quantified CRtime, (qCRtime), was obtained through polarized reflectance imaging and a software program. In Paper II, CRtests were performed on pediatric patients in an emergency department and video filmed, and qRCtimes were obtained. The video films were shown to health care staff in a pediatric clinic, and the staff was asked to assess CRtime with naked eye. In Paper III, healthy volunteers were subjected to lower body negative pressure, (LBNP), in a blood loss shock model and CRtests performed and qCRtimes obtained. In Paper IV, the qCRtimes from the healthy study subjects in the LBNP model were compared with simultaneous changes in perfusion, measured as speed resolved perfusion reflecting flow in different vessels, and tissue oxygenation was also measured.

Results: In Paper I, there were no statistical differences in qCRtime in a series of CRtests, regardless of when in the series the test was performed. In Paper II, naked eye assessment of CRtimes in children showed poor reproducibility in pediatric nurses and pediatricians, as well as in comparison to qCRtimes. In Paper III, in a blood loss shock model, qCRtimes shortened statistically significantly. In Paper IV, the shortened qCRtimes in Paper III, correlated to a decrease in perfusion and in tissue oxygenation as well as reduced flow in the smallest vessels.

Conclusion: The CRtest shows good repeatability, but the test, as it is commonly performed in clinical practice with naked eye assessment, could be questioned for its lack of reproducibility. The CRtest also shows shortening of qCRtime in a blood loss shock model, contradictory to previously believed. The shortening of qCRtime is associated with changes in perfusion. Objective methods for quantification of CRtime with biooptical imaging techniques, as in these studies with polarized reflectance imaging, is valuable in the study of the CRtest and changes in perfusion in provocations and hemodynamic stress.

Place, publisher, year, edition, pages
Linköping: Linköping University Electronic Press, 2026. p. 56
Series
Linköping University Medical Dissertations, ISSN 0345-0082 ; 2012
Keywords
Microcirculation, Shock, Bio-optical imaging
National Category
Other Clinical Medicine
Identifiers
urn:nbn:se:liu:diva-219989 (URN)10.3384/9789181183160 (DOI)9789181183153 (ISBN)9789181183160 (ISBN)
Public defence
2026-01-23, Hasselquistsalen, Building 511, Campus US, Linköping, 09:00 (English)
Opponent
Supervisors
Available from: 2025-12-15 Created: 2025-12-15 Last updated: 2025-12-17Bibliographically approved

Open Access in DiVA

fulltext(1987 kB)66 downloads
File information
File name FULLTEXT01.pdfFile size 1987 kBChecksum SHA-512
21728cdaf8bfd642263f86528d1f9fb83a73aef161a1fbec320e569283781fdc6541cec1938bf1e34b4491031b05102420c205ea0813289588698f3928cf7d0b
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMedScopus

Search in DiVA

By author/editor
Meyer, FridaStahre, JonatanHenricson, JoakimWilhelms, Daniel
By organisation
Division of Clinical Chemistry and PharmacologyFaculty of Medicine and Health SciencesDepartment of Emergency Medicine in LinköpingDepartment of Biomedical and Clinical SciencesH.K.H. Kronprinsessan Victorias barn- och ungdomssjukhus
In the same journal
BMC Emergency Medicine
Health Care Service and Management, Health Policy and Services and Health Economy

Search outside of DiVA

GoogleGoogle Scholar
Total: 66 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 220 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf