liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Estimating the plasma volume by infusing albumin: a retrospective feasibility study
Karolinska Inst Danderyds Hosp KIDS, Sweden.
Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Anaesthetics, Operations and Specialty Surgery Center, ANOPIVA US. Linköping University, Department of Biomedical and Clinical Sciences, Division of Surgery, Orthopedics and Oncology.
2025 (English)In: Intensive Care Medicine Experimental, E-ISSN 2197-425X, Vol. 13, no 1, article id 35Article in journal (Refereed) Published
Abstract [en]

Background The combined changes in plasma albumin and blood hemoglobin can probably be used to estimate the plasma volume (PV) when albumin is infused. However, the optimal setup, timing of the blood sampling, and the importance of capillary leakage to the calculations are unclear. Methods In this technical vignette, we estimated the PV using retrospective data on plasma albumin and blood hemoglobin obtained during intravenous infusion of 3 mL/kg of 20% albumin over 30 min in 41 volunteers and 45 patients. We used a manual and a kinetic correction for capillary leakage of albumin. The results were compared to the mean of two anthropometric equations derived via tracer methods. Results The anthropometric PV was 3.00 +/- 0.63 L (mean +/- SD). The strongest linearity between the albumin-derived and anthropometric PV was obtained at the end, and 10 min after the end, of the 30-min infusions; the correlation coefficient was 0.75 over this time frame. The difference between the two measures (the prediction error) was 0.31 +/- 0.56 L but the SD was only half as high for PVs< 2.5 L than for larger PVs. There was slightly stronger linearity and better accuracy, but no better precision, when data were corrected for capillary leakage. Conclusion This study suggests how an evaluation of this method using isotopes can be conducted. Changes in plasma albumin and blood hemoglobin have the best chance to accurately indicate the PV at the end of, or 10 min after, a 30-min infusion of albumin. Subtraction of 0.3 L from the PV is sufficient to correct for capillary leakage of albumin.

Place, publisher, year, edition, pages
SPRINGER , 2025. Vol. 13, no 1, article id 35
Keywords [en]
Plasma volume; Plasma albumin; Pharmacokinetics; Anthropometry; Body composition
National Category
Anesthesiology and Intensive Care
Identifiers
URN: urn:nbn:se:liu:diva-213312DOI: 10.1186/s40635-025-00743-xISI: 001469417700001PubMedID: 40108100Scopus ID: 2-s2.0-105000970521OAI: oai:DiVA.org:liu-213312DiVA, id: diva2:1955146
Note

Funding Agencies|Karolinska Institute; Grifols

Available from: 2025-04-29 Created: 2025-04-29 Last updated: 2026-07-22

Open Access in DiVA

fulltext(2196 kB)66 downloads
File information
File name FULLTEXT01.pdfFile size 2196 kBChecksum SHA-512
dfd17c4e596dcba7bd917174a0ec71e3593536d478a1a9772d5868cecadd902c57119704ff7d16c06891727318db7229201fab1fc668b6afc326db916ba58aaf
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMedScopus

Authority records

Zdolsek, Joachim

Search in DiVA

By author/editor
Zdolsek, Joachim
By organisation
Faculty of Medicine and Health SciencesANOPIVA USDivision of Surgery, Orthopedics and Oncology
In the same journal
Intensive Care Medicine Experimental
Anesthesiology and Intensive Care

Search outside of DiVA

GoogleGoogle Scholar
Total: 66 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 68 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf