Accurate fully automated assessment of left ventricle, left atrium, and left atrial appendage function from computed tomography using deep learningShow others and affiliations
2024 (English)In: European Heart Journal - Imaging Methods and Practice, E-ISSN 2755-9637, Vol. 2, no 4, article id qyaf011Article in journal (Refereed) Published
Abstract [en]
Aims: Assessment of cardiac function is essential for diagnosis and treatment planning in cardiovascular disease. Volume of cardiac regions and the derived measures of stroke volume (SV) and ejection fraction (EF) are most accurately calculated from imaging. This study aims to develop a fully automatic deep learning approach for calculation of cardiac function from computed tomography (CT).
Methods and results: Time-resolved CT data sets from 39 patients were used to train segmentation models for the left side of the heart including the left ventricle (LV), left atrium (LA), and left atrial appendage (LAA). We compared nnU-Net, 3D TransUNet, and UNETR. Dice Similarity Scores (DSS) were similar between nnU-Net (average DSS = 0.91) and 3D TransUNet (DSS = 0.89) while UNETR performed less well (DSS = 0.69). Intra-class correlation analysis showed nnU-Net and 3D TransUNet both accurately estimated LVSV (ICCnnU-Net = 0.95; ICC3DTransUNet = 0.94), LVEF (ICCnnU-Net = 1.00; ICC3DTransUNet = 1.00), LASV (ICCnnU-Net = 0.91; ICC3DTransUNet = 0.80), LAEF (ICCnnU-Net = 0.95; ICC3DTransUNet = 0.81), and LAASV (ICCnnU-Net = 0.79; ICC3DTransUNet = 0.81). Only nnU-Net significantly predicted LAAEF (ICCnnU-Net = 0.68). UNETR was not able to accurately estimate cardiac function. Time to convergence during training and time needed for inference were both faster for 3D TransUNet than for nnU-Net.
Conclusion: nnU-Net outperformed two different vision transformer architectures for the segmentation and calculation of function parameters for the LV, LA, and LAA. Fully automatic calculation of cardiac function parameters from CT using deep learning is fast and reliable.
Place, publisher, year, edition, pages
2024. Vol. 2, no 4, article id qyaf011
Keywords [en]
cardiac segmentation; computed tomography; deep learning; left ventricular ejection fraction; stroke volume; vision transformer
National Category
Medical Imaging
Identifiers
URN: urn:nbn:se:liu:diva-215519DOI: 10.1093/ehjimp/qyaf011PubMedID: 40051867OAI: oai:DiVA.org:liu-215519DiVA, id: diva2:1975646
Note
Funding agencies: Knut and Alice Wallenberg Foundation to SciLifeLab for research in Data-driven Life Science, DDLS (KAW 2020.0239), Swedish Research Council (2022-03931), the Swedish Heart and Lung Foundation (20210441), Region Östergötland (RÖ-987498), and Analytic Imaging Diagnostics Arena (AIDA, ID 2312). The computations and data handling were enabled by resources provided by the National Academic Infrastructure for Supercomputing in Sweden (NAISS) at Linköping University partially funded by the Swedish Research Council (Vetenskapsrådet) through grant agreement no. 2022-06725.