liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Multi-sequence 3D MRI fusion for paediatric brain tumour classification using deep learning
Linköping University, Department of Computer and Information Science, The Division of Statistics and Machine Learning.
2025 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesisAlternative title
Multisekvensfusion för pediatrisk hjärntumörklassificering av 3D MRI med djupinlärning (Swedish)
Abstract [en]

Paediatric brain tumours are a severe type of diseases with treatment plans varying by diagnosis, which is typically determined by radiological imaging. Recent deep learning projects perform diagnosis classification using a single 3D magnetic resonance imaging sequence type, or fusing 2D sequences with improved performance. This thesis aims to investigate the possibility of diagnosis classification as well as the related tumour location classification using 3D MRI deep learning models trained on either a single, or multiple distinct 3D MRI sequence types.

In this project, 243 pairs of T1W-GD and T2W MRI sequences of patients with paediatric brain tumours were analysed. Two classification tasks were considered: braintumour diagnosis classification (classes glioma, ependymoma and medulloblastoma) and tumour location classification (classes infratentorial and supratentorial). Three models were considered; a (vision transformer) Swin UNETR architecture trained by [1] named BrainSegFounder connected to a dense neural network, the ResNet (2+1)D and the ResNetMixed from [2] (both convolutional neural networks). The models utilized either early or intermediate fusion of sequences. The models were evaluated with various metrics: class-wise precision, class-wise recall, overall accuracy, balanced accuracy and balanced ROC-AUC. Models trained on single sequences and multiple sequences respectively were statistically compared using Wilcoxon signed rank tests on the predicted probability of the true class of each observation across models.

For diagnosis classification, overall classification performance was poor compared to random chance. The models were generally able to achieve high precision and recall values for glioma, and very low values for ependymoma and medulloblastoma. No model achieved balanced accuracy above 0.5, and the balanced ROC-AUC values were in the range [0.5, 0.66]. One model achieved significantly better true class prediction probabilities when trained on fused T1W-GD and T2W sequences as compared to T1W-GD sequences, but classifications were still poor by both models. The poor performance was investigated, and deemed to likely be caused by over-fitting as a consequence of the limited training data.

For the tumour location classification task, the models were able to achieve predictions marginally better than random chance. Recall values were larger than the class proportions, and balanced ROC-AUC values were in the range [0.7, 0.82]. No model trained on paired T1W-GD and T2W sequences was significantly better than corresponding single sequence models. The ResNet (2+1)D model achieved balanced accuracies 0.63, 0.59, 0.68 when trained on T1W-GD, T2W, and fused T1W-GD and T2W sequences respectively. The ResNet Mixed model achieved balanced accuracies 0.8, 0.68, 0.66 when trained on T1W-GD, T2W, and fused T1W-GD and T2W sequences respectively.

Place, publisher, year, edition, pages
2025. , p. 45
Keywords [en]
Machine learning, Deep Learning, tumour classification, tumor classification, medical foundation model, brain tumour segmentation
National Category
Radiology and Medical Imaging Artificial Intelligence
Identifiers
URN: urn:nbn:se:liu:diva-216056ISRN: LIU-IDA/STAT-A--25/016--SEOAI: oai:DiVA.org:liu-216056DiVA, id: diva2:1983250
Presentation
2025-06-04, Linköping, 11:10 (English)
Supervisors
Examiners
Available from: 2025-08-11 Created: 2025-07-10 Last updated: 2025-08-11Bibliographically approved

Open Access in DiVA

fulltext(4156 kB)147 downloads
File information
File name FULLTEXT01.pdfFile size 4156 kBChecksum SHA-512
5534d9a6c099bc0ec9232d5b99a6b251e89aef697816d4aa5c6763503b74625b6146c86b45cb6a2babd29c13b1f6169322edc43bf077f3544961f23576411fab
Type fulltextMimetype application/pdf

By organisation
The Division of Statistics and Machine Learning
Radiology and Medical ImagingArtificial Intelligence

Search outside of DiVA

GoogleGoogle Scholar
Total: 150 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 687 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf