liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Only fair accuracy of the radiographic classification of adult proximal humeral fractures in the Swedish Fracture Register: a cohort analysis
Linköping University, Department of Biomedical and Clinical Sciences, Division of Surgery, Orthopedics and Oncology. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Center for Surgery, Orthopaedics and Cancer Treatment, Department of Orthopaedics in Linköping.
Linköping University, Department of Biomedical and Clinical Sciences, Division of Surgery, Orthopedics and Oncology. Linköping University, Faculty of Medicine and Health Sciences. Ryhov Cty Hosp, Sweden.
Linköping University, Department of Biomedical and Clinical Sciences, Division of Surgery, Orthopedics and Oncology. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Center for Surgery, Orthopaedics and Cancer Treatment, Department of Orthopaedics in Linköping. Örebro Univ, Sweden.ORCID iD: 0000-0001-7873-3093
Linköping University, Department of Biomedical and Clinical Sciences. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Center for Surgery, Orthopaedics and Cancer Treatment, Department of Orthopaedics in Linköping.
Show others and affiliations
2025 (English)In: Injury, ISSN 0020-1383, E-ISSN 1879-0267, Vol. 56, no 8, article id 112558Article in journal (Refereed) Published
Abstract [en]

Introduction Quality registers are used for quality assessment, cost analyses, and research regarding outcomes of surgical and non-operative treatments. As the Swedish Fracture Register (SFR) expands, and is used as a platform for randomized trials, assuring reliability and accuracy of the data is essential. Aim This study aimed to investigate the accuracy of the radiographic classification data for proximal humerus fractures recorded in the SFR. Method All radiographic images of 171 patients with a proximal humerus fracture registered in the SFR between 2019 and 03-01 and 2019-08-31 at 3 hospitals were included. The radiographs were independently assessed at 2 occasions >3 weeks apart by 1 surgeon at each center and IRR was calculated to validate the modification of the AO/OTA classification used in the register. A "gold standard" classification for each patients' images was then established with a consensus discussion involving 4 shoulder surgeons. The gold standard classification was compared with the classification registered in the SFR. Results Intra-rater reliability was moderate (kappa 0.549-0.596) with percent agreement (PA) 61-66 %. Inter-rater reliability was also moderate (kappa 0.508-0.557) with PA 58-62 %. Accuracy of the SFR recordings compared with gold standard was fair with kappa 0.36 (95 % CI 0.297-0.425) and PA 44 %. Conclusion For registers to be of use the accuracy of data is essential as well as coverage, completeness, validity and reliability. The modified AO/OTA classification for proximal humerus fractures used in the SFR had moderate reliability but registered data only fair accuracy compared with a gold standard. This questions its value as a base for scientific research and clinical decisions.

Place, publisher, year, edition, pages
ELSEVIER SCI LTD , 2025. Vol. 56, no 8, article id 112558
Keywords [en]
Accuracy; Proximal humeral fracture; Classification; Register; Trauma
National Category
Orthopaedics
Identifiers
URN: urn:nbn:se:liu:diva-216461DOI: 10.1016/j.injury.2025.112558ISI: 001533832600001PubMedID: 40639131Scopus ID: 2-s2.0-105009879710OAI: oai:DiVA.org:liu-216461DiVA, id: diva2:1990158
Available from: 2025-08-19 Created: 2025-08-19 Last updated: 2025-09-24

Open Access in DiVA

fulltext(2556 kB)101 downloads
File information
File name FULLTEXT01.pdfFile size 2556 kBChecksum SHA-512
fc81c1489373485fb86f79d41b8c16b769a0afc1cb7c0fd81a65af820f557336b4ce925608440abf57a9edee6015486dfb8ab5050f42c144404d51acd4959a5f
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMedScopus

Search in DiVA

By author/editor
Lundin, PerDettmer, AnneAdolfsson, LarsSandquist, SofiaBjörnsson Hallgren, Hanna
By organisation
Division of Surgery, Orthopedics and OncologyFaculty of Medicine and Health SciencesDepartment of Orthopaedics in LinköpingDepartment of Biomedical and Clinical Sciences
In the same journal
Injury
Orthopaedics

Search outside of DiVA

GoogleGoogle Scholar
Total: 101 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 63 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf