liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Ventilationsbaserad CO2-infångning i universitetsmiljöer för ett koldioxidneutralt universitet
Linköping University, Department of Management and Engineering, Energy Systems. Linköping University, Faculty of Science & Engineering.ORCID iD: 0000-0002-0604-3672
Linköping University, Department of Management and Engineering, Energy Systems. Linköping University, Faculty of Science & Engineering.
2026 (Swedish)Report (Other academic)
Sustainable development
Climate Improvements, Environmental work
Alternative title
Ventilation-Based CO2 Capture in University Environments for a Carbon-Neutral University (English)
Abstract [sv]

Projektet har undersökt potentialen för att använda Direct Air Capture (DAC) integrerat i ventilationssystem för att fånga in metabolisk och atmosfärisk CO₂ i universitetsmiljöer. En uppgraderad laboratoriebaserad testanläggning med zeolit 13X har utvecklats, där särskilt fukthaltens inverkan på infångningseffektiviteten har studerats genom installation av en avfuktare som möjliggör kontrollerad styrning av luftfuktigheten.

De experimentella resultaten visar att reducerad fukthalt är avgörande för hög infångningsgrad, där en relativ fuktighet om cirka 8 % möjliggjorde en CO₂-infångning på över 90 %, jämfört med omkring en tredjedel utan avfuktning. 

Den tekno-ekonomiska potentialbedömningen omfattar samtliga campusområden vid Linköpings universitet och visar en total årlig infångningspotential om 8 031 ton CO₂. Den tillhörande energianvändningen uppgår till 4 015 MWh el och 12 046 MWh värme per år, vilket motsvarar energikostnader på 10 MSEK per år. De potentiella intäkterna från försäljning av infångad CO₂ beräknas till 20 MSEK per år, vilket ger en årlig avkastning på 10 MSEK när energikostnaderna beaktas. Även om installationskostnader för DAC-enheterna och möjliga intäkter från koldioxidkrediter inte ingår i beräkningarna, indikerar resultaten att DAC-teknik kan utgöra en betydelsefull komponent i arbetet mot koldioxidneutrala universitetsmiljöer.

Abstract [en]

The project investigated the potential of using Direct Air Capture (DAC) integrated into ventilation systems to capture metabolic and atmospheric CO₂ in university environments. An upgraded laboratory-based test facility using zeolite 13X was developed, with particular emphasis on studying the impact of humidity on capture efficiency through the installation of a dehumidifier that enables controlled regulation of air moisture levels.

The experimental results demonstrate that reduced humidity is critical for achieving high capture efficiency. A relative humidity of approximately 8% enabled CO₂ capture rates exceeding 90%, compared with around one-third without dehumidification. The techno-economic assessment included all campus areas of Linköping University and shows a total annual capture potential of 8,031 tonnes of CO₂. The associated energy use amounts to 4,015 MWh of electricity and 12,046 MWh of heat per year, corresponding to annual energy costs of approximately SEK 10 million. Potential revenues from the sale of captured CO₂ are estimated at SEK 20 million per year, resulting in an annual net return of SEK 10 million when energy costs are considered. Although installation costs for the DAC units and potential revenues from carbon credits were not included in the analysis, the results indicate that DAC technology can represent a significant component in efforts toward carbon-neutral university environments.

Place, publisher, year, edition, pages
Linköping: Linköping University Electronic Press, 2026. , p. 12
National Category
Energy Systems Environmental Sciences
Identifiers
URN: urn:nbn:se:liu:diva-221082DOI: 10.3384/rapport-221082OAI: oai:DiVA.org:liu-221082DiVA, id: diva2:2036594
Funder
Linköpings universitet, Klimatkompensationsfonden
Note

Granskning:

Arbetet har granskats internt av projektets forskargrupp, där metodval, resultat och slutsatser har kvalitetssäkrats genom gemensam genomgång och vetenskaplig diskussion. 

Available from: 2026-02-09 Created: 2026-02-09 Last updated: 2026-08-06Bibliographically approved

Open Access in DiVA

fulltext(789 kB)100 downloads
File information
File name FULLTEXT01.pdfFile size 789 kBChecksum SHA-512
c6291cfcb62dca9695db82d2b3d17387b6c11267b6121c13488efa7767609236e9af0363e4a418ca4435c781d0db39d2b8ad4a3194b3ccc136b394908a23a279
Type fulltextMimetype application/pdf

Other links

Publisher's full texthttps://libris.kb.se/vgqrhmf9ssqh2g2b

Authority records

Milić, VlatkoMoshfegh, Bahram

Search in DiVA

By author/editor
Milić, VlatkoMoshfegh, Bahram
By organisation
Energy SystemsFaculty of Science & Engineering
Energy SystemsEnvironmental Sciences

Search outside of DiVA

GoogleGoogle Scholar
Total: 105 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 4713 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf