liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Intraoperative 3D quantitative magnetic resonance imaging in paediatric brain tumour surgery
Linköping University, Department of Health, Medicine and Caring Sciences, Division of Diagnostics and Specialist Medicine. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Center of Paediatrics and Gynaecology and Obstetrics, H.K.H. Kronprinsessan Victorias barn- och ungdomssjukhus. Linköping University, Center for Medical Image Science and Visualization (CMIV).ORCID iD: 0000-0001-8921-431X
Linköping University, Department of Biomedical and Clinical Sciences, Division of Surgery, Orthopedics and Oncology. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Anaesthetics, Operations and Specialty Surgery Center, Department of Neurosurgery.ORCID iD: 0000-0003-4404-5828
Linköping University, Department of Biomedical and Clinical Sciences, Division of Children's and Women's Health. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Center of Paediatrics and Gynaecology and Obstetrics, H.K.H. Kronprinsessan Victorias barn- och ungdomssjukhus.
Linköping University, Department of Health, Medicine and Caring Sciences, Division of Diagnostics and Specialist Medicine. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Center for Diagnostics, Medical radiation physics. Linköping University, Center for Medical Image Science and Visualization (CMIV).ORCID iD: 0000-0002-3423-5348
Show others and affiliations
2026 (English)In: PLOS ONE, E-ISSN 1932-6203, Vol. 21, no 2, article id e0332562Article in journal (Refereed) Published
Abstract [en]

Purpose center dot To investigate if R1 and R2 can reliably be measured using 3D quantitative MRI in an intraoperative setting when paediatric brain tumour surgery is performed. center dot To determine whether B1+ inhomogeneities affect R1 and R2 measurements in normal-appearing white matter and the thalamus, respectively, and how R1 and R2 measurements are affected by different coils. center dot To assess how the relaxation parameters of brain tissue are affected by the intraoperative setting.Purpose center dot To investigate if R1 and R2 can reliably be measured using 3D quantitative MRI in an intraoperative setting when paediatric brain tumour surgery is performed. center dot To determine whether B1+ inhomogeneities affect R1 and R2 measurements in normal-appearing white matter and the thalamus, respectively, and how R1 and R2 measurements are affected by different coils. center dot To assess how the relaxation parameters of brain tissue are affected by the intraoperative setting.Purpose center dot To investigate if R1 and R2 can reliably be measured using 3D quantitative MRI in an intraoperative setting when paediatric brain tumour surgery is performed. center dot To determine whether B1+ inhomogeneities affect R1 and R2 measurements in normal-appearing white matter and the thalamus, respectively, and how R1 and R2 measurements are affected by different coils. center dot To assess how the relaxation parameters of brain tissue are affected by the intraoperative setting.Methods The accuracy of R1 and R2, the effect of B1+-field inhomogeneity and how the flex coil position affected R1 and R2 were evaluated, both pre- and intraoperatively during surgery. Ten patients were recruited, six girls and four boys aged 2-15 years, with varying tumour entities, all referred to surgery with intraoperative MR. The patients were scanned using a head coil preoperatively and flex coils intraoperatively. Control experiments were performed on phantoms in various positions, equivalent to the patient positions. ROIs (Regions of Interest) were positioned in areas representing normal-appearing matter. Relaxation rates R1 and R2 were calculated from 3D-quantification using an interleaved Look-Locker acquisition sequence with T2 preparation pulse (3D-QALAS) data.Results There was a significant increase of R2 in the intraoperative setting compared to the preoperative 3D-QALAS measurements. In contrast to the patient examinations, control experiments using relaxation phantoms did not demonstrate similar differences.Conclusion Relaxometry is feasible in the intraoperative setting. The detected differences between the quantitative R2 values in tissue pre- and intraoperatively seem to be explained by the physiological conditions characterising the surgical situation.

Place, publisher, year, edition, pages
PUBLIC LIBRARY SCIENCE , 2026. Vol. 21, no 2, article id e0332562
National Category
Radiology and Medical Imaging
Identifiers
URN: urn:nbn:se:liu:diva-221768DOI: 10.1371/journal.pone.0332562ISI: 001693802500006PubMedID: 41701731Scopus ID: 2-s2.0-105030167790OAI: oai:DiVA.org:liu-221768DiVA, id: diva2:2044703
Note

Funding Agencies|Wallenberg Centre for Molecular and Translational Medicine; The Joanna Cocozza Foundation for Children's (SE); Barncancerfonden; Mary Bves Stiftelse fr Barncancerforskning; ALF (SE); Research Support in the Field of Cancer at Linkping University/County Council of stergtland

Available from: 2026-03-10 Created: 2026-03-10 Last updated: 2026-04-22

Open Access in DiVA

fulltext(1501 kB)29 downloads
File information
File name FULLTEXT01.pdfFile size 1501 kBChecksum SHA-512
22f06384dedd6cd55062a5658fb05461010042e8e60ab871d272117aa34599c44c055e0d72eafa22560a5ef802cda32c881a9e9e7773353658c3f1486d4b64b3
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMedScopus

Search in DiVA

By author/editor
Nyman, PerHolmgren, RafaelNordh, EmmaLjusberg, AnnaSnödahl, OscarBlystad, IdaLundberg, PeterTisell, Anders
By organisation
Division of Diagnostics and Specialist MedicineFaculty of Medicine and Health SciencesH.K.H. Kronprinsessan Victorias barn- och ungdomssjukhusCenter for Medical Image Science and Visualization (CMIV)Division of Surgery, Orthopedics and OncologyDepartment of NeurosurgeryDivision of Children's and Women's HealthMedical radiation physicsDepartment of Radiology in Linköping
In the same journal
PLOS ONE
Radiology and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar
Total: 29 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 39 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf