liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Experimental Investigation of Wall Confluent Jets on Transparent Large-Space Building Envelopes: Part 2-Application in Cooling Greenhouses
Univ Gävle, Sweden.
Univ Gävle, Sweden.
Linköping University, Department of Management and Engineering, Energy Systems. Linköping University, Faculty of Science & Engineering. Univ Gävle, Sweden.
2026 (English)In: Energies, E-ISSN 1996-1073, Vol. 19, no 4, article id 875Article in journal (Refereed) Published
Abstract [en]

This study experimentally evaluated the performance of a wall confluent jet (WCJ) cooling system in a greenhouse under real summer and autumn weather conditions. It examined the effects of indoor air temperature setpoint (Tspt), number of nozzle rows (n) on the WCJ diffuser, and external wall shading on WCJ's cooling performance. Thermocouples and constant-current anemometers measured air and surface temperatures and air velocity, while pyranometers measured solar radiation. The WCJ system dynamically regulated inlet air temperature between 14 degrees C and 25 degrees C to counter solar and conductive heat gains, maintaining indoor air temperature within +/- 1.5 degrees C of the setpoint. Increasing Tspt by 4 degrees C reduced inlet cooling demand by 25% but increased indoor air temperature by 20-25% and raised ceiling, wall, and floor surface temperatures by 17%, 20%, and 16%, respectively. Increasing n reduced surface temperatures by up to 8% and indoor air temperature by 6%. External wall shading reduced solar heat gain, lowering interior surface temperatures by 10-30%, peak and mean indoor air temperatures by up to 35% and 15%, and net power peaks by 40%. Autumn conditions reduced cooling loads by 50% relative to summer. Overall, WCJ cooling demonstrates strong potential as an alternative or complementary system for greenhouse thermal regulation without increasing primary energy demand.

Place, publisher, year, edition, pages
MDPI , 2026. Vol. 19, no 4, article id 875
Keywords [en]
wall confluent jets; experimental field study; greenhouse cooling; indoor environment; greenhouse envelope shading
National Category
Building Technologies
Identifiers
URN: urn:nbn:se:liu:diva-221773DOI: 10.3390/en19040875ISI: 001700079100001Scopus ID: 2-s2.0-105031052452OAI: oai:DiVA.org:liu-221773DiVA, id: diva2:2044718
Note

Funding Agencies|Swedish Energy Agency [52686-1]

Available from: 2026-03-10 Created: 2026-03-10 Last updated: 2026-06-10

Open Access in DiVA

fulltext(6056 kB)6 downloads
File information
File name FULLTEXT01.pdfFile size 6056 kBChecksum SHA-512
435df9d0f1e4980a9c5d1a2476f834c3b04ac38ae0c3ae88d2ad9452a8211953c855adfd12436b678bbc8bdd6c9bf7b7c95a4276d4a7047e17f682b383a3573a
Type fulltextMimetype application/pdf

Other links

Publisher's full textScopusCorrection

Search in DiVA

By author/editor
Moshfegh, Bahram
By organisation
Energy SystemsFaculty of Science & Engineering
In the same journal
Energies
Building Technologies

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 24 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf