liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Evaluation of a water phantom detector-applicator setup for independent experimental verification of 106Ru ocular brachytherapy applicators
Karolinska Inst, Sweden; Karolinska Univ Hosp, Sweden.
Eckert & Ziegler Bebig GmbH, Germany.
Eckert & Ziegler Bebig GmbH, Germany.
Karolinska Inst, Sweden; Swedish Radiat Safety Author, Sweden.
Show others and affiliations
2026 (English)In: Medical Physics, ISSN 0094-2405, E-ISSN 2473-4209, Vol. 53, no 4, article id e70404Article in journal (Refereed) Published
Abstract [en]

Background 106Ru ophthalmic brachytherapy (BT) applicators are used for treating ocular tumors. While manufacturer-provided dosimetry data is commonly used for treatment planning, independent quality assurance (QA) measurements are crucial. However, there is a lack of dedicated equipment and standardized protocols for clinical verification of 106Ru depth-dose distributions.Purpose The BetaCheck-106 (TM) is a prototype compact water phantom detector-applicator setup enabling high precision alignment of 106Ru applicators and detectors. We assess the setup's compatibility with three commercially available detectors (microSilicon, microSilicon X and microDiamond) and its performance in determining full 1D depth-current curves with these detectors. In addition, data from clinical QA-tests of 20 106Ru applicators was used to estimate inhomogeneities in the applicator's 106Ru coating.Methods Measurements were conducted on two 106Ru applicators with different activity levels, one had been in clinical service for one year and one was measured before clinical use. Dose rates were recorded at 1 mm intervals from 2 mm to 10 mm in water using the BetaCheck-106 (TM) setup with the three detectors. Measurement precision and detector response were analyzed. Separately, inter-applicator variability was analyzed using the aforementioned measurements of 20 106Ru applicators.Results The BetaCheck-106 (TM) demonstrated exceptional setup reproducibility (0.23%), enabling precise depth-resolved measurements. Both of the silicon diode detectors examined provided stable and reproducible measurements. The diamond detector performed reproducibly for the high-activity applicator but exhibited depth-dependent signal instability for the low-activity source, likely due to the detector's lower sensitivity. Normalized depth-signal curves for the three detectors all had similar shape. Analysis of measured current per activity of 20 106Ru applicators revealed a depth dependent inhomogeneity effect decreasing with depth.Conclusions The BetaCheck-106 (TM) provides practical high-reproducibility positioning of detector and applicator for 106Ru applicator measurements in water. The silicon detectors successfully characterized both high and low activity applicators up to 10 mm water depth. The diamond detector proved viable for measurements of the applicator with activity 17.8-18.4 MBq, but it lost stability with depth when measuring the one-year old 8.3 MBq activity applicator.

Place, publisher, year, edition, pages
WILEY , 2026. Vol. 53, no 4, article id e70404
Keywords [en]
dosimetry; QA; Ru-106 brachytherapy
National Category
Radiology and Medical Imaging
Identifiers
URN: urn:nbn:se:liu:diva-222780DOI: 10.1002/mp.70404ISI: 001732260600001PubMedID: 41937265Scopus ID: 2-s2.0-105034832806OAI: oai:DiVA.org:liu-222780DiVA, id: diva2:2052671
Note

Funding Agencies|Swedish Radiation Safety Authority [SSM2022-6507]; Swedish Cancer Foundation [24 0927 FK, 24 3786 PJ]

Available from: 2026-04-14 Created: 2026-04-14 Last updated: 2026-06-27

Open Access in DiVA

fulltext(756 kB)10 downloads
File information
File name FULLTEXT01.pdfFile size 756 kBChecksum SHA-512
9076dceb7c55aa797e9d618c61338fc5e97befd0ef2da257150ff28f3d36f3cd16ac535284b742a28beca1111f1f49d7725a6677dbbd397b882999b35fab0359
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMedScopus

Search in DiVA

By author/editor
Carlsson Tedgren, Åsa
By organisation
Division of Diagnostics and Specialist MedicineFaculty of Medicine and Health Sciences
In the same journal
Medical Physics
Radiology and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar
Total: 10 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 21 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf