Quantitative determination of gadolinium and iodine contrast agents in dual-energy computed tomography via a dual-energy iterative reconstruction algorithm: a simulation study on multi-contrast imaging
Linköping University, Department of Electrical Engineering, Computer Vision. Linköping University, Faculty of Science & Engineering. Linköping University, Center for Medical Image Science and Visualization (CMIV).ORCID iD: 0000-0002-9072-2204
Linköping University, Department of Health, Medicine and Caring Sciences, Division of Diagnostics and Specialist Medicine. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Center for Diagnostics, Medical radiation physics. Linköping University, Center for Medical Image Science and Visualization (CMIV).ORCID iD: 0000-0003-3352-8330
Linköping University, Department of Health, Medicine and Caring Sciences, Division of Diagnostics and Specialist Medicine. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Center for Surgery, Orthopaedics and Cancer Treatment, Department of Radiation Physics. Linköping University, Center for Medical Image Science and Visualization (CMIV). Karolinska Univ Hosp, Sweden.ORCID iD: 0000-0002-4549-8303
Linköping University, Department of Health, Medicine and Caring Sciences, Division of Diagnostics and Specialist Medicine. Linköping University, Faculty of Medicine and Health Sciences. Linköping University, Center for Medical Image Science and Visualization (CMIV).ORCID iD: 0000-0003-1257-2383
2026 (English)In: Radiation Protection Dosimetry, ISSN 0144-8420, E-ISSN 1742-3406, Vol. 202, no 3, p. 268-275Article in journal (Refereed) Published
Abstract [en]

Simultaneous quantification of two contrast agents in dual-energy CT (DECT) is promising for clinical diagnostics. This simulation study demonstrates that accurate estimation of iodine and gadolinium concentrations in unmixed aqueous solutions can be achieved using two-material decomposition and beam-hardening suppression with the dual-energy iterative reconstruction algorithm (DIRA). A simulated DECT imaging chain was used for evaluation. The phantom comprised a lipid cylinder containing five inserts filled with water, iodine (25 and 50 mg/mL), and gadolinium (25 and 50 mg/mL) solutions. X-ray projections at 80 and Sn140 kV were generated using Siemens' DRASIM code. DIRA was configured for two-material decomposition with water-bone, water-iodine, and water-gadolinium bases, and cylinder positions were manually defined during reconstruction. After approximately six iterations, accurate estimates of contrast agent mass fractions were obtained. These results confirm the feasibility of simultaneous iodine and gadolinium quantification in DECT and support further development toward a clinical application.

Place, publisher, year, edition, pages
OXFORD UNIV PRESS , 2026. Vol. 202, no 3, p. 268-275
National Category
Radiology and Medical Imaging Computer Vision and Learning Systems
Identifiers
URN: urn:nbn:se:liu:diva-223095DOI: 10.1093/rpd/ncaf163ISI: 001712982100021PubMedID: 41821457Scopus ID: 2-s2.0-105032709512OAI: oai:DiVA.org:liu-223095DiVA, id: diva2:2054653
Note

Funding Agencies|Vetenskapsrdet [VR-NT 2016-05033]; Patientskerhetsforskning Region stergtland [LiO-724181]; ALF Grants Region stergtland [LiO-602731]; Cancerfonden [CAN 2017/1029, CAN 2018/622]

Available from: 2026-04-21 Created: 2026-04-21 Last updated: 2026-06-27

Open Access in DiVA

fulltext(870 kB)30 downloads
File information
File name FULLTEXT01.pdfFile size 870 kBChecksum SHA-512
11ef96d6e1fee57c8c9c53a2a66525de764bd8244079f1f47dd90d0b0e8239652956b60cf6daff0433260e6d2d573a635f8cf9b0a3f8b1fa6f3f1b8ea7474379
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMedScopus

Search in DiVA

By author/editor
Magnusson, MariaSandborg, MichaelCarlsson Tedgren, ÅsaMalusek, Alexandr
By organisation
Computer VisionFaculty of Science & EngineeringCenter for Medical Image Science and Visualization (CMIV)Division of Diagnostics and Specialist MedicineFaculty of Medicine and Health SciencesMedical radiation physicsDepartment of Radiation Physics
In the same journal
Radiation Protection Dosimetry
Radiology and Medical ImagingComputer Vision and Learning Systems

Search outside of DiVA

GoogleGoogle Scholar
Total: 30 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 30 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf