A 25-year evaluation of direct local international normalized ratio calibration of the Owren type prothrombin time method in Sweden
Lund Univ, Sweden.
Equalis AB, Sweden.
Equalis AB, Sweden.
Lund Univ, Sweden; Univ & Reg Labs Reg Skåne, Sweden.
Show others and affiliations
2026 (English)In: Journal of Thrombosis and Haemostasis, ISSN 1538-7933, E-ISSN 1538-7836, Vol. 24, no 5, p. 1643-1653Article in journal (Refereed) Published
Abstract [en]

Background: All hospital laboratories in Sweden use the Owren prothrombin time (PT) method primarily to monitor anticoagulant treatment. Direct international normalized ratio (INR) calibration was introduced in 1999 under the supervision of Equalis, the national organization for external quality assessment (EQA) in laboratory medicine. Objectives: We present 25 years of combined experience in developing a national calibration procedure and conducting INR EQA. Methods: Since the introduction of direct INR calibration, 14 different Equalis INR calibrator kits have been produced. Variability between laboratories and across different reagent and calibrator lots was determined (>51 000 results and 96 EQA materials). The stability of the calibrators and the calibration procedure were evaluated through remeasurements of the calibrators, weekly warfarin dosing in patient records, and a comparison study with an international reference thromboplastin (RBT/05). Results: Interlaboratory variability was significantly improved after the introduction of direct INR calibration. Results were consistent over 25 years, with a mean coefficient of variation < 6% in the therapeutic range. The INR calibrators showed reproducible measurements, and the calibration procedure was stable over time. Furthermore, anticoagulated patients had a stable mean weekly warfarin dose relative to the mean INR. The Owren's PT agreed with the Quick PT in a direct comparison with RBT/05. Conclusion: There is good agreement among PT measurements across Swedish laboratories, with no significant differences in reagents. The user-friendly, unique calibration procedure, including the preparation of certified plasmas, improved the performance of national PT measurements and has been shown to remain stable over decades.

Place, publisher, year, edition, pages
ELSEVIER SCIENCE INC , 2026. Vol. 24, no 5, p. 1643-1653
Keywords [en]
calibration; international normalized ratio; laboratory proficiency testing; prothrombin time; warfarin
National Category
Pediatrics
Identifiers
URN: urn:nbn:se:liu:diva-224252DOI: 10.1016/j.jtha.2025.12.030ISI: 001762975400001PubMedID: 41655786Scopus ID: 2-s2.0-105031567925OAI: oai:DiVA.org:liu-224252DiVA, id: diva2:2062607
Available from: 2026-05-26 Created: 2026-05-26 Last updated: 2026-07-02

Open Access in DiVA

fulltext(2375 kB)15 downloads
File information
File name FULLTEXT01.pdfFile size 2375 kBChecksum SHA-512
0f4bfbe90b72c57026897566e2a6d4ce399135c7228721b93e06b011b853e619dd9a95eb65acfffacb235aee4ca11159b061fb140ee6147a82b31de46fc07233
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMedScopus

Search in DiVA

By author/editor
Lindahl, Tomas
By organisation
Division of Clinical Chemistry and PharmacologyFaculty of Medicine and Health SciencesDepartment of Clinical Chemistry
In the same journal
Journal of Thrombosis and Haemostasis
Pediatrics

Search outside of DiVA

GoogleGoogle Scholar
Total: 15 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 28 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf