liu.seSearch for publications in DiVA
Planned maintenance
A system upgrade is planned for 17/11-2026, at 12:00-13:00. During this time DiVA will be unavailable.
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Improved coronary CT angiography image quality using photon-counting detector CT in SCAPIS reexamination: scan protocol and comparative analysis
Örebro Univ, Sweden.
Linköping University, Department of Health, Medicine and Caring Sciences. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Center for Diagnostics, Department of Radiology in Linköping.
Lund Univ, Sweden; Skåne Univ Hosp, Sweden.
Uppsala Univ, Sweden.
Show others and affiliations
2026 (English)In: European Journal of Radiology, ISSN 0720-048X, E-ISSN 1872-7727, Vol. 201, article id 112920Article in journal (Refereed) Published
Abstract [en]

Objectives: The Swedish CArdioPulmonary bioImage Study reexamination (SCAPIS reexamination) is the first population-based study to employ coronary CT angiography (CCTA) using photon-counting detector CT (PCD-CT). It includes 15,000 participants from SCAPIS baseline. This work aims to describe the PCD-CT protocol in SCAPIS reexamination, compare diagnostic image quality with energy-integrating detector CT (EID-CT) at SCAPIS baseline, and assess the comparability of Agatston scores and degree of stenosis between the studies. Methods: The PCD-CT protocol in SCAPIS reexamination is provided. CCTA data from 1,147 participants in SCAPIS reexamination (51% women, age 65 [IQR 61-69]) and 29,554 participants in SCAPIS (52% women, age 58 [54-61]) were analyzed. The image quality in eleven proximal and middle coronary segments was compared, stratified by Agatston score. Agatston scores and stenosis degree were compared in age-and sex-matched samples. Results: Full diagnostic image quality was more frequent in SCAPIS reexamination (1,036/1,147, 90%) compared with SCAPIS baseline (20,468/26,188, 78%), p < 0.001, despite a higher calcium burden (Agatston score 8 [0-106] vs. 0 [0-20]). Of participants with Agatston score > 400, 89/116, 77%, and 246/945, 26%, had full diagnostic image quality, respectively, p < 0.001. Agatston score distributions and stenosis >= 50% were similar in matched samples (p = 0.51 and p = 0.08). Of those with > 50% stenosis at SCAPIS baseline, 30% (12/40) were reclassified to < 50% in SCAPIS reexamination. Conclusion: The optimized PCD-CT protocol in SCAPIS reexamination provided high image quality, irrespective of Agatston scores, outperforming the EID-CT protocol used at SCAPIS baseline. Agatston scores were comparable, but potential differences in stenosis grading warrant further investigation.

Place, publisher, year, edition, pages
ELSEVIER IRELAND LTD , 2026. Vol. 201, article id 112920
Keywords [en]
Coronary arteries; Cardiac CT; Photon-counting detector CT; Image quality; Coronary CT angiography
National Category
Radiology and Medical Imaging
Identifiers
URN: urn:nbn:se:liu:diva-224381DOI: 10.1016/j.ejrad.2026.112920ISI: 001770664700001PubMedID: 42127646Scopus ID: 2-s2.0-105038467552OAI: oai:DiVA.org:liu-224381DiVA, id: diva2:2064810
Note

Funding Agencies|Swedish CArdioPulmonary bioImage Study (SCAPIS); Knut and Alice Wallenberg Foundation; Swedish Research Council; VINNOVA (Sweden's Innovation agency); University of Gothenburg and Sahlgrenska University Hospital, Karolinska Institutet and Region Stockholm, Linkouml;ping University - Region Ouml;rebro lauml; [OLL-959996]; Swedish Heart-Lung Foundation

Available from: 2026-06-02 Created: 2026-06-02 Last updated: 2026-07-02

Open Access in DiVA

fulltext(2953 kB)27 downloads
File information
File name FULLTEXT01.pdfFile size 2953 kBChecksum SHA-512
5ad1d32be88c9f49dcbb453a8adcb868a99966d23c1aca85e7f1e26ee7c9903055d1f0c1bbe48951954c6c7842338af6ef1a7561547c8e638ca816828c161bca
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMedScopus

Search in DiVA

By author/editor
Nyberg, GustenHenriksson, LilianPersson, AndersSandstedt, Mårten
By organisation
Department of Health, Medicine and Caring SciencesFaculty of Medicine and Health SciencesDepartment of Radiology in LinköpingDivision of Diagnostics and Specialist MedicineCenter for Medical Image Science and Visualization (CMIV)
In the same journal
European Journal of Radiology
Radiology and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar
Total: 27 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 40 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf