liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Reactive Power Control in a Pulp and Paper Industry: An Evaluation of Synchronous Machine Excitation and Capacitor Bank Switching
Linköping University, Department of Electrical Engineering, Vehicular Systems.
Linköping University, Department of Electrical Engineering, Vehicular Systems.
2026 (English)Independent thesis Advanced level (degree of Master (Two Years)), 28 HE creditsStudent thesis
Abstract [en]

The Swedish electrical production mix is changing from a system dominated by large synchronous generators to a system with a higher share of renewable energy that utilizes power electronic inverters. This transition complicates reactive power balance management, which is critical for maintaining grid voltage stability and reducing losses. Reactive power is managed regionally by the so-called distribution system operator (DSO) by, among other methods, imposing consumption limits on large reactive power users such as electricity intensive large industries.

Industrial plants commonly operate induction machines, which are inductive loads and thus by definition consumers of reactive power. To compensate for these, many industries utilize capacitor banks which provide a capacitive load, which counteracts the induction machines' reactive power consumption. These banks, however, provide only discrete steps in reactive power management which may sometimes over or under-compensate. In the studied plant they are also manually controlled, leading to a limitation in response time. An alternative solution is the use of synchronous machines, which can be magnetized to both produce and consume reactive power independent of their active power output. Furthermore, an opportunity exists to operate a synchronous machine in idle solely for reactive power support, as a so called synchronous condenser.

The objective of this thesis is to investigate how the total reactive power at a Swedish pulp and paper industry can be controlled to stay within the DSO-imp-osed limits. As these threshold over-steps are billed based on 60-minute averages, the control also needs to be fast enough. This leads to the two research questions. The first question relates to which methods can be used to control reactive power control and the potential these methods have, while the second relates to how automatic control strategies can be implemented to improve the response time of the controllers.

The work consists of two main parts, supported by a comprehensive theory chapter. The first part analyzes reactive power measurements from the studied plant and how this data compares to the DSO limits. These measurements are also integral for the second part where simulations are conducted to show how the control of existing capacitor banks and the potential of synchronous machine excitation can reduce the level down to the limits. Furthermore, automatic control strategies are studied to analyze how fast and coordinated control can be achieved.

The findings indicate that automatic, dynamic synchronous machine reactive power control provides a fast and continuous method which improves flexibility through both added capability and a fast response time. This is also the case for the synchronous condenser. The results also show that capacitor banks serve an important role in compensating high steady-state reactive power demand and therefore act as an important complement to synchronous machine excitation.

Place, publisher, year, edition, pages
2026. , p. 67
Keywords [en]
Reactive power, synchronous motor, capacitor bank, control, excitation, industry, paper, paper and pulp, TMP
National Category
Power Systems and Components
Identifiers
URN: urn:nbn:se:liu:diva-225146ISRN: LiTH-ISY-EX--26/5845--SEOAI: oai:DiVA.org:liu-225146DiVA, id: diva2:2074576
External cooperation
Holmen Board and Paper AB
Subject / course
Vehicular Systems
Presentation
2026-06-04, Systemet, B-Huset, Campus Valla, Linköping, 13:15 (Swedish)
Supervisors
Examiners
Available from: 2026-06-18 Created: 2026-06-17 Last updated: 2026-06-18Bibliographically approved

Open Access in DiVA

fulltext(9551 kB)108 downloads
File information
File name FULLTEXT01.pdfFile size 9551 kBChecksum SHA-512
30c23d962c7b7fbd08952e59cbf576fd81026af88344fa0441c521e3bb124ec360d80db80823653e1146f4f078d374cd3f436ae3452121fc4323fdec9551797c
Type fulltextMimetype application/pdf

By organisation
Vehicular Systems
Power Systems and Components

Search outside of DiVA

GoogleGoogle Scholar
Total: 108 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 225 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf