Corals require calcium to grow a healthy skeleton by dissolving CO2 and calcium in the water using a calcium reactor. Bubbles calculate the flow of CO2 added to a coral cultiva- tion aquarium. A Bubble counting device was created. Bubble detection was tested using capacitive sensing. Observing the changes in capacitance between air and water to sense the bubbles passing by the sensor. An embedded system was built using an Arduino UNO, and capacitance was measured with a capacitive-to-digital converter IC. With warnings if CO2 flow deviates. The signal from the bubbles was weak and overpowered by noise. The system was not sufficient for detecting air bubbles in water. Instead, it proved more useful as an object detector rather than a bubble detector.