A HPLC system for separation and determination of methylxanthines and selected drugs has been developed. Teophylline, 1-methylxanthine, 3-methylxanthine, 1,3-dimethyluric acid, caffeine, paracetamol, furosemide, dexamethasone, prednisolone, cefazolin and imipenem have been determined. A RP-18e column with a RP-18 pre-column and a DAD detector were used. Gradient elution with 0.05% TFA aqueous solution with acetononitrile at the flow rate of 0.8 mL min-1 was applied. The developed system was used to determine the examined compounds in urine samples.