Development of a harmonised method for the profiling of amphetamines: III. Development of the gas chromatographic method
Swedish National Laboratory of Forensic Science.
National Bureau of Investigation, Finland.
University of Lausanne.
University of Strathclyde, Glasgow.
Show others and affiliations
2007 (English)In: Forensic Science International, ISSN 0379-0738, E-ISSN 1872-6283, Vol. 169, no 1, p. 50-63Article in journal (Refereed) Published
Abstract [en]

This study focused on gas chromatographic analysis of target compounds found in illicit amphetamine synthesised by the Leuckart reaction, reductive amination of benzyl methyl ketone, and the nitrostyrene route. The analytical method was investigated and optimised with respect to introduction of amphetamine samples into the gas chromatograph and separation and detection of the target substances. Sample introduction using split and splitless injection was tested at different injector temperatures, and their ability to transfer the target compounds to the GC column was evaluated using cold on column injection as a reference. Taking the results from both techniques into consideration a temperature of 250 °C was considered to be the best compromise. The most efficient separation was achieved with a DB-35MS capillary column (35% diphenyl 65% dimethyl silicone; 30 m × 0.25 mm, df 0.25 μm) and an oven temperature program that started at 90 °C (1 min) and was increased by 8 °C/min to 300 °C (10 min). Reproducibility, repeatability, linearity, and limits of determination for the flame ionisation detector (FID), nitrogen phosphorous detector (NPD), and mass spectrometry (MS) in scan mode and selected ion monitoring (SIM) mode were evaluated. In addition, selectivity was studied applying FID and MS in both scan and SIM mode. It was found that reproducibility, repeatability, and limits of determination were similar for FID, NPD, and MS in scan mode. Moreover, the linearity was better when applying FID or NPD whereas the selectivity was better when utilising the MS. Finally, the introduction of target compounds to the GC column when applying injection volumes of 0.2 μl, 1 μl, 2 μl, and 4 μl with splitless injection respectively 1 μl with split injection (split ratio, 1:40) were compared. It was demonstrated that splitless injections of 1 μl, 2 μl, and 4 μl could be employed in the developed method, while split injection and splitless injections of 0.2 μl should be avoided.

Place, publisher, year, edition, pages
Elsevier , 2007. Vol. 169, no 1, p. 50-63
Keywords [en]
Amphetamine; Impurities; Profiling; Optimisation; Separation; Gas chromatography–mass spectrometry
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:liu:diva-72288DOI: 10.1016/j.forsciint.2006.10.018ISI: 000247113600007Libris ID: 9496800OAI: oai:DiVA.org:liu-72288DiVA, id: diva2:459017
Available from: 2011-11-24 Created: 2011-11-24 Last updated: 2023-06-21Bibliographically approved
In thesis
1. Development of a Method for Comparing Amphetamine Samples
Open this publication in new window or tab >>Development of a Method for Comparing Amphetamine Samples
2004 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

The studies presented in this thesis were part of a pan-European project, and they describe the research performed to develop a method for comparing amphetamine samples. The work included the following: optimisation of a method for profiling of amphetamine by gaschromatography (GC); optimisation of a technique for preparing samples for GC analysis; testing and evaluation of the abilities of a number of distance metrics to discern links between amphetamine samples originating from the same batch of synthesis analysed using the method developed in the current studies.

Street amphetamine contains hundreds of different by-products (target compounds), many of which have been identified and found to come from the different conditions used in the manufacturing process. Therefore, the main objective of developing the GC method was to optimise separation and quantification of the target compounds. The best separation was achieved using a DB-35MS capillary column. For quantification, mass spectrometry (MS) in the scan mode employing one target ion seemed to perform best, because this technique provided superior selectivity, and also made it possible to use mass spectra to identify target compounds. In addition, MS detection proved to offer excellent between-laboratory reproducibility.

The conditions used to prepare amphetamine samples for liquid-liquid extraction (LLE) andsolid-phase extraction (SPE) were also optimised. The sample preparation methods gave similar results but it was easier to use LLE, hence it was chosen for further sample preparation.

The ability of various numerical methods to find links between amphetamine samples was tested on GC-MS data of 26 target compounds that had been transformed by various pretreatment techniques. The best results were obtained when using Pearson correlation applied to data transformed by normalisation followed by applying fourth root.

It was also demonstrated that the amphetamine profiling method developed in the current studies was superior to a procedure already in use in a number of forensic laboratories in Europe.

Place, publisher, year, edition, pages
Linköping: Linköping University, 2004. p. 57
Series
Linköping Studies in Science and Technology. Dissertations, ISSN 0345-7524 ; 879
National Category
Organic Chemistry
Identifiers
urn:nbn:se:liu:diva-179057 (URN)9173739626 (ISBN)
Public defence
2004-05-27, Majoren, Brigaden, Linköpings garnisonsområde, Linköping, 10:15
Opponent
Note

All or some of the partial works included in the dissertation are not registered in DIVA and therefore not linked in this post.

Available from: 2021-09-09 Created: 2021-09-09 Last updated: 2023-02-23Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Authority records

Dahlén, Johan

Search in DiVA

By author/editor
Dahlén, Johan
In the same journal
Forensic Science International
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 330 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf